Installing The Server Into The Rack - Supero A+ SERVER 1022G-NTF User Manual

A+ server 1022g-ntf
Hide thumbs Also See for A+ SERVER 1022G-NTF:
Table of Contents

Advertisement

A
R
+ SE
VER 1022G-NTF User's Manual

Installing the Server into the Rack

You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. Do this by lining up the rear of the chassis
rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping
the pressure even on both sides (you may have to depress the locking tabs when
inserting). See Figure 2-3 for details.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click".
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the floor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
Warning: Do not pick up the server with the front handles. They are de-
signed to pull the system from a rack only.
Figure 2-3. Installing the Server into a Rack
2-6

Advertisement

Table of Contents
loading

Table of Contents