ELECTRICAL
INSTALLATION
ALL
Centers
ELECTRICLaundry
_
The following
are specific
requirements
for proper
and safe electrical
installation
of your laundry
center.
Failure
to follow
these instructions
can create
an
electrical
shock and/or
a fire hazard.
This appliance
MUST be properly
grounded.
Electrical
shock can result if the laundry
center
is not properly
grounded. Follow
the instructions
in this manual
for proper
grounding.
Do not use an extension
cord with this
laundry
centen
Some extension
cords are not designed
to
withstand
the amounts
of electrical
current
this laundry
center
utilizes
and can melt, creating
electrical
shock and/or
fire hazard.
Locate the laundry
center within
reach of the receptacle
for the
length
power
cord
to be purchased,
allowing
some slack in the
cord.
Refer to the pre-installation
requirements
in this manual
for
the proper
power
cord to be purchased.
_
A U.L. approved
strain relief must be
installed
onto
power
cord. If the strain relief is not attached,
the
cord can be pulled out of the laundry
center
and can be cut by
any movement
of the cord,
resulting
in electrical
shock.
_Do
not use an aluminum
wired
receptacle
with
a copper
Wired
power
cord and pluq (or vice versa). A chemical
reaction
occurs
between
copper
and aluminum
and can cause
electrical
shorts.
The proper
wiring
and receptacle
is a copper
wired
power
cord with
a copper
wired
receptacle
OR
aluminum
wired
power
cord with
an aluminum
wired
receptacle.
NOTE: Laundry
centers
operating
on a 208 volt power
supply will
have longer
drying
times than
laundry
centers
operating
on a 240
volt
power
supply.
Canadian
ELECTRIC
Laundry
Center
]
_
Improper
connection
of the equipment
grounding
conductor
can result in a risk of electrical
shock,
Check
with
a licensed electrician
if you are in doubt
as to whether
the
appliance
is properly
grounded,
For a grounded cord connected laundry center:
1. The laundry
center
MUST
be grounded.
In the event of
malfunction
or breakdown,
grounding
will reduce
the risk of
electrical
shock by providing
a path
of least resistance
for
the electrical
current.
2. Since your
laundry
center
is equipped
with
a power
supply
cord
having
an equipment-grounding
conductor
and a
grounding
plug, the plug MUST
be plugged
into an appropriate
outlet
that is properly
installed
and grounded
in accordance
with
all codes and ordinances.
If in doubt,
call a licensed
electrician.
ELECTRICAL
CONNECTIONS
FOR A 4-WIRE
SYSTEM
GREEN GROUND
GREEN
SCREW
RED"
GROUNDING
REQUIREMENTS
Non-Canadian
ELECTRIC
Laundry
Center
_
Improper
connection
of the equipment
grounding
conductor
can result in a risk of electrical
shock.
Check
with
a licensed
electrician
if you are in doubt
as to whether
the
appliance
is properly
grounded.
For a grounded
cord-connected
laundry
center:
I. The laundry
center
MUST
be grounded.
In the event of
malfunction
or breakdown,
grounding
will reduce
the risk of
electrical
shock by a path of least resistance
for electrical
current.
2. If your
laundry
center
is equipped
with
a power
supply
cord
having
an equipment-grounding
conductor
and a grounding
plug,
the plug MUST
be plugged
into an appropriate,
copper
wired
receptacle
that
is properly
installed
and grounded
in
accordance
with
all local codes and ordinances.
If in doubt,
call a licensed
electrician.
For a permanently
connected
laundrv
center:
The
laundry
center
MUST
be connected
to a grounded
metal,
permanent
wiring
system;
or an equipment
grounding
con-ductor
MUST
be run with
the circuit
conductors
and connected
to the
equipment-grounding
terminal
or lead on the appliance.
1. Remove the screw securing
the terminal
block access
cover to the rear panel and remove
cover.
2. Install a U.L. approved
strain
relief connector
in the entry
hole on the back panel.
3. Insert a NEMA
14-30 Type ST or SRDT, U.L. approved
power
cord through
the strain
relief.
4. Attach
the green power
cord ground
wire to the cabinet
with
the green ground
screw.
5. Attach
the white
(neutral)
wire from
the power
cord to the
silver-colored
center
terminal
on the terminal
block.
Tighten
the screw securely.
6. Attach
the red and black wires from the power
cord to the
outer
brass-colored
terminals
on the terminal
block.
Tighten
both
screws securely.
7. Tighten
the screws securing
the cord restraint
firmly
against
the power
cord.
8. Reinstall the terminal
block access cover.
I
ALL GASLaundry
Centers
1. The laundry
center, when
installed,
MUST
be electrically
grounded
in accordance
with
local codes,
or in the absence
of local codes, with
the National
Electrical
Codes, ANSI/
NFPA (latest edition)
or in Canada,
CSA C22.1
CanadianElectrical
Code Part 1.