Drain System; Exhaust System Requirements - Frigidaire FFLE2022MW1 Installation Manual

Laundry center
Table of Contents

Advertisement

Available languages

Available languages

Drain system
requirements
:[
Drain capable of eliminating 17 gals (64.3 L) per minute.
2
A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
3
The standpipe height above the floor should be:
Minimum height:
33 in. (84 cm)
Maximum height:
96 in. (244 cm)
96"
(244cm)
max,
T
33"
(84cm)
rain.
i=1
Exhaust
system
requirements
vent hood which has a swing-out damper(s) that open when the dryer is in
operation. When the dryer stops, the dampers automatically
close to prevent
drafts and the entrance of insects and rodents. To avoid restricting the outlet,
maintain a minimum of 12 inches (30.5 cm) clearance between the vent hood
and the ground or any other obstruction.
FIRE HAZARD
fire hazards.
....
The following are specific requirements for proper and safe opera-
tion
of your
dryer.
FIRE HAZARD
Do not install a clothes dryer with flexible plastic or metal foil venting
materials. Flexible venting materials are known to collapse, be easily
crushed and trap lint. These conditions will obstruct clothes dryer airflow
and increase the risk of fire.
:If your present system is made up of plastic duct or metal foil duct, replace it
with a rigid or semi-rigid metal duct. Also, ensure the present duct is free of
any lint prior to installing dryer duct.
Incorrect