6.3

LED Display and Display Monitoring

The LED display provides the user with the operating frequency, function settings, and
status information necessary to easily monitor and set the operating parameters. The
individual LED's are identified and explained in the following chart.
5
4
2
Item
Name
1
Monitor display
2
Panel control LED
3
Option mode LED
4
Monitor display
5
6
Hz display LED
7
% display LED
8
Time display LED
TOSHIBA
1
MANUAL CONTROL
Display Monitoring
Function/status
7-segment, 4-column LED
Displays frequency, title, data, etc.
ON when the unit is in the manual control mode
OFF when the unit is in the auto (remote) control mode
FLASHING when the unit is in the manual control mode and the motor is running
ON when the computer interface option is enabled. (Contact Toshiba
for information.)
Both LED's are normally OFF when the monitor is displaying operating
frequency or scaled operating frequency from the display scaler.
LED 5 is ON and LED 4 is OFF when unit is in a patterned run sequence.
Both LED's are ON when the unit is in the parameter setting mode using
the operating panel keypad and the motor is not running.
Both LED's are FLASHING when the unit is in the parameter setting mode
using the operating panel keypad and the motor is running.
LED 4 is ON and LED 5 is OFF when the unit is in the parameter setting
mode and the operating panel keypad is disabled.
(Computer Command Mode)
ON when the display is indicating frequency.
ON when the display is indicating a percentage.
ON when displaying time in seconds.