BYPASSING ZONES

If you wish to bypass one or more zones, this must be done while the system
is in the disarmed state. The following steps are used for bypassing zones:
Step 1
Press the [BYPASS] key.
Step 2
Enter user code, if required (optional). The bypass light flashes.
Step 3
Enter 1 or 2 digits indicating the zone you wish to bypass, i.e. press
the [1] key for zone 1, press [1]-[2] for zone 12.
Step 4
Press the [BYPASS] key again.
Step 5
The corresponding zone light will illuminate indicating the zone has
been bypassed. Repeat steps 3 and 4 for any other zone(s) that
need to be bypassed.
Step 6
Press the [BYPASS] key again -or- press the [#] key to exit the
Bypass Mode. The bypass light will stop flashing upon exiting the
Bypass Mode.

GROUP BYPASS

By pressing the [BYPASS] key, followed by the [0] key, then the [BYPASS]
key again, all zones that are designated as group bypass zones will be
bypassed. Press the [BYPASS] key again to exit group bypassing.

UNBYPASSING

To manually unbypass zones, perform the bypassing procedure on a zone that
is already bypassed. The corresponding light for that zone will go off when
unbypassed. NOTE: All zones will automatically be unbypassed each
time the system is disarmed.

TURNING THE DOOR CHIME ON AND OFF

The door chime is turned on or off by pressing the [CHIME] key while the
system is in the disarmed state. If the chime is on the chime light will be
illuminated. If the chime is off, the chime light will be off. Each press of the
[CHIME] key will toggle the chime feature on/off and produce a momentary
ding-dong sound.