QuickSpecs
Additional Options
HP Rack Series
HP Rack Series
HP Rack Series
HP Rack Series
Rack 10000 G2 Series
Rack 10000 G2 Series
Rack 10000 G2 Series
Rack 10000 G2 Series
HP 10642 G2 1200mm deep Shock Rack
HP 10647 G2 1200mm deep Shock Rack
HP 10642 G2 Pallet Universal Rack
HP 10642 G2 Shock Universal Rack
NOTE: Please see the QuickSpecs for Technical Specifications and additional
NOTE:
NOTE:
NOTE:
information:
http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html
(Worldwide)
NOTE:
NOTE:
NOTE: For additional information regarding Rack Cabinets, please see the following
NOTE:
URL: http://www.hp.com/go/rackandpower.
NOTE: The increasing power of new high-performance processor technology requires
NOTE:
NOTE:
NOTE:
increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks
provide enhanced airflow for maximum cooling, allowing these racks to be fully
loaded with servers using the latest processors.
CAUTION:
CAUTION:
CAUTION: If a third-party rack is used, observe the following additional requirements
CAUTION:
to ensure adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear
doors, you must allow 830 square inches (5,350 sq cm) of hole evenly
distributed from top to bottom to permit adequate airflow (equivalent to the
required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels
of the rack must be a minimum of 2.75 inches (7 cm).
CAUTION:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-
CAUTION:
CAUTION:
spaces in the rack. This arrangement ensures proper airflow. Using a rack without
blanking panels results in improper cooling that can lead to thermal damage.
NOTE: HP ProLiant DL rack models have fixed rails which provide support for racks
NOTE:
NOTE:
NOTE:
with round mounting holes and tool-free support for racks with square mounting holes
(including Compaq/HP 7000, 9000, 10000 and HP series), with an adjustment
range of 26" - 36".
NOTE:
NOTE:
NOTE: Support for all 2 and 4 post Telco racks and threaded hole racks requires an
NOTE:
additional option kit from Rack Solutions. The Rack Solutions brackets can be
purchased at: www.hp.com/go/rackandpower.
DA - 13504
Worldwide — Version 18 — November 14, 2011
HP ProLiant DL120 Generation 6 (G6)
HP ProLiant DL120 Generation 6 (G6)
HP ProLiant DL120 Generation 6 (G6)
HP ProLiant DL120 Generation 6 (G6)
AF092A
AF094A
AF001A
AF002A