Vent Information and Diagrams

A. Vent Table Key
The abbreviations listed in this vent table key are used in
the vent diagrams.
Symbol
V
Minimum Vertical Run Length 14 ft.
MIN
V
Maximum Vertical Run Length 50 ft.
MAX
B. Horizontal Venting
Horizontal venting is NOT allowed.
C. Measuring Standards
Vertical measurements listed in the vent diagram (Figure
5.1) were made using the following standard:
• Vertical terminations are measured to top of chimney.
Figure 5.1
10
Description
V= 14 FT. MINIMUM
50FT. MAXIMUM
INSULATION OR ANY OTHER
COLLAR ATTACHMENT
Heatilator • ADI-ZCFB-S • 2032-910 Rev. i • 6/09
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a
chimney fl ue serving a separate solid fuel or
gas burning appliance.
• May impair safe operation of this appliance
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
ALL vent specifi cations MUST be followed.
• This product is tested and listed to these specifi cations.
• Appliance performance will suffer if specifi cations are not
followed.
TERMINATION
CAP
FLASHING
INLET AIR COLLAR
EXHAUST COLLAR
EXHAUST
VENT PIPE
3 INCH COLLAR
(Factory installed to
stainless steel section)
WARNING: DO NOT
BLOCK PIPE END WITH
SEALING MATERIAL
STAINLESS STEEL
PIPE - 3 FT. MIN.
REQUIRED (INCLUDED)
SEAL DAMPER
AREA
INLET AIR
VENT PIPE
BRACKET
WARNING
or other appliances connected to the fl ue.
CAUTION