Check List

Failure : No cooling (the aggregate at the back of the device is cold).
Possible Cause
a.) The device plug is not
plugged in.
b.) No voltage in socket.
c.) The electronics or the sensor
is faulty.
Does the LED flash ?
d.) Defective heating element.
e.) The device is in its defrosting
phase.
Failure : No cooling (the aggregate is warm).
Possible Cause
a.) The device is not level.
Leakage test ?
b.) The device was only
switched on a short while
ago.
c.) Defective cooling unit.
Failure : Poor cooling performance.
Possible Cause
a.) The cooling aggregate is not
sufficiently ventilated.
b.) The device is exposed to
direct sunlight.
c.) The fridge door does not
close tightly
d.) The fridge was stocked a
short while ago.
Failure : Frost formation in fridge.
Possible Cause
a.) The fridge door does not
close tightly.
Self Help
a.) Plug in device plug.
b.) Check main fuse.
e.) See operating instruction
5.3
Self Help
a.) Level the device using a
spirit level.
b.) Switch on the device and
let it run for 5-6 hours.
Self Help
a.) Check that the ventilation
grids are not covered.
Check that device has
been installed properly
(installation instruction 4.5).
b.) Follow installation
instruction 4.5.
c.) Check installation in line
4.5 + 4.8 .
d.) Check fridge after
5-6 hours for proper
cooling function.
Self Help
a.) Check installation is in line
with 4.5 + 4.8.
13
Authorised Service
c.) Install new
electronics or sensor.
d.) Install new heating
element.
Authorised Service
c.) Exchange device.
Authorised Service
c.) Install new doorseal,
if necessary.
Authorised Service
a.) Install new doorseal,
if necessary.