Fitting Under A Counter - Zanussi ZWD 14581 W1 User Manual

Table of Contents

Advertisement

Electrical connection
Any electrical work required to install this
appliance should be carried out by a qualified
electrician or competent person.
WARNING!
This appliance must be earthed.
The manufacturer declines any liability
should this safety measure not be
observed.
Before switching on, make sure the electricity
supply voltage is the same as that indicated
on the appliance's rating plate.
IMPORTANT!
Information on the electrical connection is
given on the rating plate on the inner edge
of the appliance door.
The appliance is supplied with a 13amp plug
fitted. In the event of having to change the
fuse in the plug supplied, a 13amp ASTA
approved (BS1363/A) fuse must be used.
Should the plug need to be replaced for any
reason, proceed as described below.
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow ..............................- Earth
Blue ....................................................- Neutral
Brown..................................................- Live
coloured green and yellow.
The wire coloured blue must be connected to
the terminal marked «N» or coloured black.
The wire coloured brown must be connected
to the terminal marked «L» or coloured red.
34
The wire coloured
green and yellow must
be connected to the
terminal marked with
the letter «E» or by the
earth symbol
or
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp
must be secure over the outer sheath.
WARNING!
A cut off plug inserted into a 13 amp socket
is a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safely. Should the appliance power supply
cable need to be replaced, this must be
carried out by our Service Force Centre.
The power supply cable must be easily
accessible after installing the appliance.
Permanent connection
In the case of permanent connection it is
necessary that you install a double pole switch
between the appliance and the electricity
supply (mains), with a minimum gap of 3mm
between the switch contacts and of a type
suitable for the required load in compliance
with the current electrical regulations.
The switch must not break the yellow and
green earth cable at any point.

Fitting under a counter

WARNING!
Before any work to the appliance, you must
disconnect the plug from the power socket.
Important!
For safety reasons, it is dangerous to fit the
appliance under a counter without the steel
plate, which you can order in your nearest
Service Force Centre.
If the counter is too
low and it becomes
necessary to remove
the top lid of the
washer-dryer, a steel
plate, known as a
height reduction kit,
must be used.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents