It is recommended that End of Season Cleaning and the Annual Service are coordinated to happen at
the same time for best results.
HARMAN DIRECT VENT COAL STOKER( DVC 500 C ) WIRING DIAGRAM
POWER CORD
MALE / FEMALE
WIRE CONNECTORS
DRAFT MOTOR
18-3 RUBBER CORD
PART NO. 3-89-08193 Rev A
maintenance Schedule
wiring diagram
TO ROOM SENSOR
SPLICE
BLACK
WHITE
GREEN
300 WATTS
-- 2.5 A. --
ESP
CONTROL
BOARD
ROOM
SENSOR
BLUE&BLACK
YELLOW&WHITE
FSS 1-10-163
FIREBOX STATIC
SENSOR
TCP
X
BLACK
BLACK
18-3 RUBBER CORD
COMBUSTION BLOWER
120 VOLTS A.C. 60 HZ.
25
ESP PROBE
(RED TWISTED)
(RED TWISTED)
YELLOW TAPE ON ENDS
1
3
4
5
6
7
8
9
10
FEEDER MOTOR
11
DISTRIBUTION BLOWER
TCP PROBE