GAS HOOK-UP INSTRUCTIONS

CYLINDER CONNECTION:
valve. Insert the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand tighten clockwise.
system is replaced.
PROPANE CYLINDER INSTALLATION:
PROPANE GAS HOOK-UP:
grommet. Insert the quick connect hose end into the regulator outlet.
NATURAL GAS HOOK-UP:
designed for natural gas and certified for outdoor use. The gas grill is designed to operate at an inlet pressure of 7 inches water
column. A regulator must be installed if the house pressure is greater than 7 inches water column. Piping and valves upstream of
the quick disconnect are not supplied. The quick disconnect must not be installed in an upward direction and a readily accessible
manual shut-off valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The flared end of the hose
must be connected to the unit as illustrated in the
licensed gas installer. Leak test all joints prior to using the gas grill.
Connect the 20" hose from the manifold, to the side burner as illustrated in the
supply hose to the flare connection which faces down from the side burner. Tighten all connections using two wrenches. (

LEAK TESTING INSTRUCTIONS

LEAK TESTING: This must be done before initial use, annually and whenever any gas components are replaced or serviced. No
smoking while performing this test, and remove all sources of ignition. See
1. Turn all burners controls to off. Turn supply valve on.
2. Brush a half and half solution of liquid soap and water onto all joints and connections of the regulator, hose, manifolds and valves.
3. Bubbles will indicate a gas leak. Either tighten the loose joint or replace the part with one recommended by the dealer.
4. If the leak cannot be stopped, shut off the gas supply, disconnect it and have the barbecue inspected by your gas supplier or dealer.
Do not use the appliance until the leak has been corrected.
5. Turn off gas supply.
Ensure that the gas regulator hose is kink free. Remove the cap or plug from the cylinder fuel
A leak test must be performed annually, and each time a cylinder is hooked up, or if a part of the gas
Set cylinder into the hole in the bottom shelf.
Press the nylon grommet into the side panel, and pass the hose from the side burner through the
This natural gas grill is supplied with a 10ft supply hose (complete with a quick disconnect)
Do not use a flame to leak test.
diagram. These connections must be made by a
for areas to check.
diagram. Connect the

Advertisement