Changing the outer flame
nozzle (Fig. 11)
Fig. 11
16
Never use the lever on glass edges which have no trim or
frame!
- To release the rear clips, carefully raise the entire glass
panel and frame, as in Fig.10a.
Fig. 10a
- Loosen the clamp screw to release the bushing by
moving it backwards to access the main nozzle easily.
Fig. a1.
- Remove the outer flame nozzle by turning it towards the
left. Fig. a2-a3.
- Screw in the new outer flame nozzle. Fig. a3-a4.
- Adjust the distance of the airflow adjusting bushing L2
according to the value -Z-. Fig. a5.
- Tighten the clamp screw. Fig. a6.