Temperature And Humidity Ranges; Operating Recommendations; Peration - Samsung AQV09N Series User Manual

Split - type air conditioner
Hide thumbs Also See for AQV09N Series:
Table of Contents

Advertisement

Temperature and Humidity Ranges

If you check the following tables, you can use your air conditioner more efficiently.
If the air conditioner is used at...
Heating capacity
Low temperatures
Protection mechanism
Operation
Heating
Cooling
Dehumidifying
 If the outdoor temperature is as low as 32°F/0°C, the heating capacity drops up to 70~80% depending on
the operating condition.
If you use the air conditioner in temperatures over 90°F/32°C (indoor temperature), the cooling capacity may drop.

Operating Recommendations

Here are a few recommendations that you should follow when using your air conditioner.
Topic
Heating performances
Warm air circulation
Frost
High indoor and
outdoor temperatures
Power failure
Protection mechanism When the air conditioner is started immediately after being plugged in or stopped, the normal
Cooling operation
Silence Mode
6
E-
141 Kinderkamack Rd, Park Ridge, NJ 07656 Tel: 201-782-1782 Fax: 201-782-1783 Web: www.amgair.com Email: info@amgair.com
Then...
The air conditioner may stop operating for the reason of protection.
Water may leak and some malfunction may occur if the heat exchanger freezes.
Water may condense and drip from the surface of the indoor unit if you don't use
the air conditioner for an extended period of time.
Outdoor Temperature
5°F to 75°F approx.
-15°C to 4°C approx.
14°F to 115°F approx.
-10°C to 46°C approx.
14°F to 115°F approx.
-10°C to 46°C approx.
Recommendation
The heat pump function of the air conditioner absorbs heat from outside air and brings it
indoors. As the temperature of the outside air drops, the heating performance of air
conditioner will decrease. If you find that the room is not warm enough, using an additional
heating appliance is recommended.
The air conditioner circulates warm air to heat your room. It will take some time to warm the
air in your room entirely after the air conditioner turns on. Therefore, turn the air conditioner on
in advance.
When outdoor temperature is low but humidity is high, frost may form on the outdoor unit at
Heat mode.
 The heating operation stops.
 The defrost mode will be triggered automatically for 3 to 14 minutes.
No intervention is required ; after about 7 minutes, the air conditioner operates again normally.
If both indoor and outdoor temperatures are high and the air conditioner is running at HEAT
mode, the outdoor unit's fan and compressor may stop at times. This is normal;simply wait until
the air conditioner switches on again.
If a power failure occurs while the air conditioner is operating, the unit will be switched off.
When the power returns, the air conditioner starts up again automatically.
operation starts up after 3 minutes for the reason of protection.
The indoor unit may not get the selected fan speed such as Medium and Low under cooling
operation at very low outdoor temperatures for the protection of the indoor unit from ice
or frost.
During Low fan speed operation, cooling performance will be reduced. If the room does not be
cooled down when using Low fan speed operation, please adjust the indoor unit's fan speed.
When you operate Silence Mode in cooling and heating, fan speed will decrease to make noise
quieter.
As a result, the performance of the unit may be reduced.
Air Marketing Group LLC
Indoor Temperature
80°F or less
7°C or less
61°F to 0°F approx.
16°C to 3°C approx.
61°F to 0°F approx.
16°C to 3°C approx.
Indoor Humidity
-
80% or less
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aqv18n seriesAqv12n seriesAqv24n series

Table of Contents