Connect
ground wire
. Remove
center
screw
Connect ground wire (F) (green or bare) of power supply cord
under green external ground conductor screw (A). Tighten
screw.
Connect remaining wires under outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to Venting Requirements.
3-Wire Power Supply Cord Connection
Use where local codes permit connecting cabinet-ground
conductor
to neutral wire.
3-wire receptacle (NEMA
type 10-30R)
3-prong plug
Spade terminals with
upturned ends
Ring terminals
Remove center terminal block screw (B).
Connect
neutral
wire
Connect neutral wire (white or center) (C) of power supply cord
under center terminal block screw (B). Tighten screw.
Connect
remaining
wires
Connect remaining wires under outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to Venting Requirements.