Download Print this page

Ariston CISPH 640 Series Operating Instructions Manual page 5

Advertisement

Min.
d) Should the cooktop be installed directly under a
cupboard, the latter should be at least 700 mm
(millimetres) from the top, as shown in Fig. C.
e) The dimensions of the cutout for the appliance must
be those indicated in the figure D. Clamps are provided
to fasten the cooktop to counters measuring from 20
to 40 mm in thickness. To fasten the cooktop securely,
it is recommended that all the clamps be used.
Fastening Clamps - Assembly Diagram
Clamp Position for
H=30mm top
Clamp Position for
H=20mm top
N.B: Use the clamps contained in the "accessory kit."
HOOD
600
mm.
Fig. C
555 mm
Fig. D
Clamp Position for
H=40mm top
Front
Back
f) In the event the cooktop is not installed above a built-
in oven, a wood panel must be inserted as insulation.
This panel must be placed at least 20 mm from the
bottom of the cooktop itself.
Important: When installing the cooktop above a built-in
oven, the oven should be placed on two wooden strips; in
the case of a joining cabinet surface, remember to leave
a space of at least 45 x 560 mm at the back.
When installing the cooktop above a built-in oven without
forced ventilation, ensure that there are air inlets and
outlets for ventilating the interior of the cabinet adequately.
Gas Connection for Cooktop
The cooktop should be connected to the gas supply by an
authorized installer. During installation of this product it is
essential to fit an approved gas tap to isolate the supply
from the appliance for the convenience of any subsequent
removal or servicing. Connection of the appliance to the
gas mains or liquid gas tanks must be carried out
according to the safety standards currently in force, and
only after it is ascertained that it is suitable for the type of
gas to be used. If not, follow the instructions indicated in
the section entitled, "Adapting the Cooktop for Different
Types of Gas". If the cooktop is to be connected to tanks
containing liquid gas, use pressure regulators that comply
with current safety standards.
Important: To insure that the appliance operates safety,
the gas is regulated correctly and your appliance lasts
over time, make sure that gas pressure levels comply with
the indications given in Table 1, "Nozzle and Burner
Specifications".
Gas Connection to Non-flexible Pipe
(copper or steel)
Connection to the gas source must be done in such a way
as to not create any stress points at any part of the
appliance.
6

Advertisement

loading

This manual is also suitable for: