2-4. PIPE FORMING AND DRAIN PIPING
2-4-1.
PIPE
FORMING
• Place the drain hose below the refrigerant
piping.
• Make sure that the drain hose is not crowded or bent.
• Do not pull the hose when applying the tape.
• When the drain hose passes the room, be sure to wrap it with insulation
material
(field-supplied).
Note:
Make sure not to damage the cover of refrigerant pipe when attaching
it back on with
Liquidpipe
Gas pipe
Indoor/outdoor
unit
connecting
wire (A)
Felt tape (7)
Piping tape (G)
Left or left-rear piping
Note:
Be sure to reattach the drain hose and the drain cap if the piping is being installed on
left or bottom left of unit, otherwise, water could drip down from the drain hose.
1)Place the refrigerant
piping and the drain hose together, then firmly apply felt tape (7)
from the end.
Felt tape (7) overlap width should be 1/3 the tape width. Use a bandage stopper at
the end of felt tape (7).
2) Pull out the drain cap at the back right of the indoor unit. (Fig. 1)
• Hold the convex section at the end and pull the drain cap.
3) Pull out the drain hose at the back left of the indoor unit. (Fig. 2)
• Hold the claw marked by the arrows and pull out the drain hose forward.
4) Put the drain cap into the section to which the drain hose is to be attached at the rear
of the indoor unit. (Fig. 3)
• Insert a screwdriver
into the hole on the cap and insert the cap fully into the drain
pan.
5) Insert the drain hose fully into the drain pan at the back right of the indoor unit. (Fig. 4)
• Check if the hose is hooked securely to the projection of its inserting part at the
drain pan.
6) Insert the drain hose into wall hole sleeve (C), and attach the upper part of indoor
unit onto the installation
plate (1). Then, shift the indoor unit completely
to the left to
make placing the piping in the back of the unit easier.
7) Cut out a piece of cardboard from the shipping box, roll it up, hook it onto the back
rib, and use it as a spacer to lift the indoor unit. (Fig. 5)
8) Connect the refrigerant piping with the extension
pipe (B).
9) Attach the lower part of the indoor unit into the installation
plate (1).
Drain cap
Fig. 1
Fig. 3
Fig. 5
........
/
Fig. 2
Drain hose
Fig. 4
Rear or bottom
piping
1) Place the refrigerant
piping and the drain hose together,
then firmly apply piping tape
(G) from the end.
2) Insert the piping and the drain hose into the wall hole sleeve (C), and attach the up-
per part of the indoor unit on the installation plate (1).
3) Check if the indoor unit is attached securely on the installation
plate (1) by moving
the unit to left and right.
4) Attach the lower part of the indoor unit into the installation
plate (1).
Remove
panel for piping on
bottom side of unit
Right piping
Note:
Before performing
the following,
make sure that wiring is completed,
and the conduit
cover is installed. (Refer to 2-3.)
1) Place the refrigerant
piping and the drain hose together, shift them to left side of the
unit, and then firmly apply piping tape (G) from the end.
2) Insert the piping and the drain hose into the wall hole sleeve (C), and attach the up-
per part of the indoor unit on the installation plate (1).
3) Check if the indoor unit is attached securely on the installation
plate (1) by moving
the unit to left and right.
4) Attach the lower part of the indoor unit into the installation
plate (1).
I
Remove panel
II II II I
I1
/
I
for piping on
II II III
I1_
1
riqht side of
/Ill
II_l
Ilfx_,PF't \
unit
To the left
2-4-2.
DRAIN
PIPING
If the extension
drain hose has to pass through a room, be sure to wrap it with insu-
lation (field-supplied).
• The drain hose should point downward
for easy drain. (Fig. 1)
If the drain hose provided with the indoor unit is too short, connect it with a field-
supplied drain hose (I). (Fig. 2)
• When connecting the drain hose to a hard vinyl chloride pipe, be sure to insert it se-
curely into the pipe. (Fig. 3)
O
Downward
slope
Fig. 1
Drain
_
flHF_
Drain hose
hose
.......
/
HI//J_- Hard vinyt chloride
I D 1-3/16 m
(70 cm)
" "
"
_.1
Softhosei.D
o .....
L
19/32 in.
(15 mm)
Diff ....
t
/_
_
I ........
I
diameter
joint
H
L
J
Fig.
2
Fig. 3
pipe
I Do not make drain piping as shown below.
I
Water
Water
leakage
leakage
Waving