Care And Maintenance; Phase Monitor Control; Phase Monitor Led Indicators; Check Charge - Payne PA10JA042000AA Installation Manual

Pa10 and pa12 electric air conditioner

Advertisement

BDHTACTDR
24VAC
COM
O
OFF:NO
24VAC
ON:OK
FLASH:PHASE
PROBLEM
@
L3
L1
0
Fig. 4i3
Phase Monitor Control
Table
2--Phase
Monitor
LED Indicators
LED
STATUS
OFF
No call for compressor
operation
FLASHING
Reversed phase
ON
Normal
A00010
PROCEDURE
II--CHECK
CHARGE
A.
Unit Charge
Factory charge is shown on unit rating plate. (See Fig. l.)Charge procedure is shown on wiring/charging
label located on unit.
CAUTION:
Compressor
damage may occur if system is overcharged.
CAUTION:
Do not vent refrigerant to atmosphere.
Recover during system repair or final unit disposal.
CARE AND MAINTENANCE
For continuing
high
performance,
and to minimize
possible
equipment
failure,
it is essential
that periodic
maintenance
be performed
on this
equipment.
Consult
your
servicing
contractor
or User's
Manual
for proper
frequency
of maintenance.
Frequency
of maintenance
may vary
depending
upon geographic
areas,
such as costal
applications.
Leave
User's
Manual
with homeowner.
Explain
system
operation
and maintenance
procedures
outlined
in manual.
.....
5 ....

Advertisement

loading

This manual is also suitable for: