TEST INSTALLED FAUCET
Move HANDLE (1) down into "off" position.
Remove AERATOR (2).
Operate handle up and down, in COLD and HOT positions,
to flush water lines thoroughly.
Replace AERATOR (2).
With HANDLE (1) down in "off" position, pull HAND SPRAY (3)
from holder and direct SPRAY END (3) into sink.
Check HAND SPRAY (3) operation:
With faucet on push BUTTON (4) to activate HAND SPRAY (3).
Release BUTTON (4) to stop spray and return
HAND SPRAY (3) to holder.
6
SERVICE
If faucet drips, operate HANDLE several times from "off" to "on." Do not
apply excessive force.
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
Remove INDEX BUTTON (1), loosen HANDLE SCREW (2)
and remove HANDLE (3).
Unthread ESCUTCHEON CAP (4). Unthread three
MOUNTING SCREWS (5).
Lift CARTRIDGE (6) off MANIFOLD (7) and remove
CARTRIDGE SEALS (8).
Clean MANIFOLD (7), CARTRIDGE (6) ports and SEALS (8).
Place SEALS (8) into CARTRIDGE PORTS (6a).
Place CARTRIDGE (6) onto MANIFOLD (7) and tighten MOUNTING
SCREWS (5) alternately.
Replace ESCUTCHEON CAP (4), HANDLE (3), tighten HANDLE
SCREW (1) and install INDEX BUTTON (2).
Test fitting.
7
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.