Foundation; Ductwork - Trane WSC036E Installation, Operation And Maintenance Manual

Packaged rooftop air conditioners precedent — heat pump 3 – 10tons – 60 hz
Table of Contents

Advertisement

Table 2.
Factory installed options (fiops)/accessory net weights (lbs)
Accessory
Barometric Relief
Belt Drive Option (3 phase only)
Coil Guards
Economizer
(c)
Electric Heaters
Hinged Doors
Manual Outside Air Damper
Motorized Outside Air Damper
Oversized Motor
Powered Convenience Outlet
Powered Exhaust
Roof Curb
Smoke Detector, Supply
Smoke Detector, Return
Through-the-Base Electrical
Unit Mounted Circuit Breaker
Unit Mounted Disconnect
(a) Weights for options not listed are <5 lbs.
(b) Net weight should be added to unit weight when ordering factory-installed accessories.
(c) Applicable to Heat Pump units only.

Foundation

If the unit is installed at ground level, elevate it above the
snow line. Provide concrete footings at each support
location with a "full perimeter" support structure or a slab
foundation for support. Refer to
operating and point loading weights when constructing a
footing foundation.
If anchoring is required, anchor the unit to the slab using
hold down bolts or isolators. Isolators should be installed
to minimize the transmission of vibrations into the
building.
WARNING
Risk of Roof Collapsing!
Confirm with a structural engineer that the roof
structure is strong enough to support the combined
weight of the roof curb and the unit. Refer to
p. 18
for typical unit and curb weights. Failure to ensure
proper structural roof support could cause the roof to
collapse, which could result in death or serious injury
and property damage.
For rooftop applications, ensure the roof is strong enough
to support the combined unit and support structural
weight. If anchoring is required, anchor the unit to the roof
with hold-down bolts or isolators. Check with a roofing
contractor for proper waterproofing.
RT-SVX23F-EN
WSC036E-048E
WSC060E
Net Weight
Net Weight
3-4 Ton
5 Ton
7
10
31
31
12
20
26
36
15
30
10
12
16
26
20
30
5
8
38
38
80
61
78
5
5
7
7
8
13
5
5
5
5
Table 1, p. 18
for the unit's
Table 1,
(a),(b)
WSC072E-090E
WSC120E
Net Weight
Net Weight
6-7½ Ton
10 Ton
10
20
36
30
12
26
30
8
38
80
78
5
7
8
5
5

Ductwork

Figure 14, p. 20
to
Figure 19, p. 21
return air openings as viewed form the rear of the unit.
Elbows with turning vanes or splitters are recommended
to minimize air noise due to turbulence and to reduce static
pressure.
When attaching the ductwork to the unit, provide a water-
tight flexible connector at the unit to prevent operating
sounds from transmitting through the ductwork.
All outdoor ductwork between the unit and the structure
should be weather proofed after installation is completed.
Installation
10
30
36
40
12
26
30
50
80
89
5
7
13
5
5
illustrate the supply and