Download Print this page

Technical Specifications - HP DL360 Specifications

Hp proliant generation 5 (g5)

Advertisement

QuickSpecs

Technical Specifications

System Unit
System Unit
System Unit
System Unit
Dimensions (H x W x D)
Dimensions
Dimensions
Dimensions
(with bezel)
Weight
Weight
Weight
Weight
(approximate)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Power Specifications
Power Specifications
Power Specifications
Power Specifications
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
System Inlet Temperature Operating
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Altitude
Altitude
Altitude
Altitude
DA - 12476
Worldwide — Version 67 — November 23, 2009
1.70 x 16.78 x 27.25 in (4.32 x 42.62 x 69.22 cm)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
NOTE:
NOTE: To review typical system power ratings use the HP Power Advisor
NOTE:
NOTE:
which is available online located at url:
efficient
or
www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL360 G5
- Follow the instructions of the next screens.
Rated Steady-State Power 700 W (at 100 VAC),
Maximum Peak Power
Non-operating
Operating
Non-operating
Operating
HP ProLiant DL360 Generation 5 (G5)
HP ProLiant DL360 Generation 5 (G5)
HP ProLiant DL360 Generation 5 (G5)
HP ProLiant DL360 Generation 5 (G5)
39.5 lb (17.92 kg)
32 lb (14.51 kg)
100 to 240 VAC
7.1 Amps (at 120VAC) to 3.5 Amps (at 240
VAC)
50 to 60 Hz
852 W
2910 BTU / hr (at 120 VAC), 2870 (at 240
VAC)
www.hp.com/go/proliant-energy-
700 W (at 200 VAC)
700 W (at 100 VAC),
700 W (at 200 VAC)
10° to 35° C (50° to 95° F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°
F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10° C/hr (18° F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30° C (86° F).
-40 to 70C (-40 to 158F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28° C (82.4° F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7° C (101.7°
F) maximum wet bulb temperature, non-
condensing.
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.