Fan Button; Timer Button; How To Set The Unit To Automatically Turn On; How To Set The Unit To Automatically Turn Off - EdgeStar PAC801W Owner's Manual

Portable air conditioner
Table of Contents

Advertisement

Fan Button

Timer Button

NOTE: To cancel the
timer, press the Power
button or set the timer to
0.0.

LED Display

Swing Button

Sleep Button

Portable Air Conditioner
The Fan button is used to change the fan speed between High Medium,
Low and Auto while in Cooling and Fan Only modes.
Press the Fan button to select the fan speed. The LED indicator light next
to the High, Medium, or Low will light up. The Automatic Fan speed
setting does not have a light.
The timer can be used to either turn the unit on or off after a number of
elapsed hours. The timer is adjustable between 1-10 hours in half-hour
increments and from 10-24 hours in one hour increments.

How to set the unit to automatically turn on

1) Press the Timer button while the unit is powered off. The Timer On indicator
LED will light up.
2) Use the Up and Down buttons to set the time (displayed in hours). The unit will
count down the time remaining. After the selected time passes, the unit will
automatically turn on.

How to set the unit to automatically turn off

1) Press the Timer button while the unit is powered on. The Timer Off indicator
LED will light up.
2) Use the Up and Down buttons to set the time (displayed in hours). The unit will
automatically count down and turn off after the selected time elapses.
Note: If the unit displays an E1 or E2 error code, the timer is cancelled.
The LED Display will show the set temperature by default. It will show the room
temperature while in Dehumidify and Fan Only modes. You can switch between
Fahrenheit and Celsius by holding both the Up and Down Buttons simultaneously
for 5 seconds. If you enabled the Timer, the LCD Display will show the hour(s)
set.

Error Codes

The display may show the following error codes:
E1 – Room temperature sensor error.
E2 – Evaporator temperature sensor error.
E4 – Display panel communication error.
If the unit displays the error codes E1, E2, or E4, power the unit off, and then
unplug the unit for 15 minutes. Plug in and power on. If the issue persists, please
contact customer service.
P1 – Bottom reservoir is full.
If the unit displays a P1 error code, drain the unit by following the "Draining the
Unit" section.
The Swing Button is used to adjust the louver swing to the desired angle. The
louver swings up to an angle of 6 degrees for each press of the button. Hold the
swing button for more than 2 seconds to initiate the auto swing features.
(Applicable to models with Swing feature only).
The Sleep Button is used to enable the Sleep mode. During the Sleep mode, the
set temperature will increase by 2 degrees after 30 minutes, then it will increase
by another 2 degrees after an additional 30 minutes and maintain this
temperature for 7 hours before it returns to the original temperature and ends the
Sleep mode. The Sleep mode is not available in Dehumidify and Fan Only
modes.
:
: