Fig. 24 - Electrolux EW30DF65GSN Installation Instructions Manual

30" free-standing dual fuel
Hide thumbs Also See for EW30DF65GSN:

Advertisement

Anti=tip bracket
installation
instructions
FASTEN BRACKET
(WALL
OR FLOOR
MOUNTING)
Leveling Leg --
---_1
1_=-1=1/4"Max.
-Wall Mount
...., Wall Plate
L
"
nt =Tip Bracket
Fig. 24
[
,_
-j
I
Floor Mount
FASTEN BRACKET
(FLOOR
MOUNTING
ONLY)
Leveling Leg --
-q
I
Floor
Mount
14F= More Than
_\
1 =1/4"
i
i
LAnti=Tip
Bracket
i',r--._ Wall
Fig. 25
Range
Side_
"
Fig. 26
Fig. 27
Electrical
requirements
3 & 4 - Wire electrical
wall Receptacle
types and
recommended
mounting
orientation
on wall
Required
for new and
remodeled
installations
4 Wire Wall
Receptacle
(14=50R)
Allowed
for
exisiting
installations
3 Wire Wall
Receptacle
(10=50R)
Fig. 28
Electrical
connection
requirements
This appliance must be properly installed and grounded by
a qualified technician inaccordance with the National Electrical
Code ANSI/NFPA No. 70 --latest edition -- and local electrical
code requirements.
This appliance may be connected
by means of permanent
"Hard Wiring" or "Power Supply Cord Kit."
When hard wiring,
do not leave excess wire in range
compartment. Excess wire in the range compartment may not
allow the access cover to be replaced properly, and could
create a potential electrical hazard if wires become pinched.
Connect only as instructed under "WIRING INSTRUCTIONS"
in Step B of the Installation Steps. When using flexible conduit
or range cable use flex connector or range cable strain relief
(See Fig. 32 on page 7).
NOTE: Only use copper wire in connection to terminal block.
Models Requiring
Power Supply Cord Kit
RISK OF FIRE OR ELECTRICAL SHOCK MAY OCC U R IF AN
INCORRECT
SIZE RANGE CORD KIT IS USED, THE
INSTALLATION INSTRUCTIONSARE
NOT FOLLOWED OR
STRAIN RELIEF BRACKETIS DISCARDED.
This appliance
may be connected
by means of a power
supply cord. Only a power supply cord kit rated at 125/250
volts minimum, and marked for use with ranges shall be
used. See chart (Fig. 29) for cord kit ampere rating information.
Cord must have either four (4) or three (3) conductors (See Fig.
28). Terminals on end of wires must be either closed loop or
open-end spade lugs with upturned ends. Cord must have
strain relief clamp. See Step B in Installation Steps for 4 or
3 - Wire connections.