Electrical Installation; Grounding Requirements; Gas Connection - Frigidaire FGQ1452HE1 Installation Instructions Manual

Gas & electric dryer
Table of Contents

Advertisement

Available languages

Available languages

ELECTRICAL INSTALLATION
I
ELECTR/CDryer
I
The following
are specific
requirements
for
proper and safe electrical installation
of your dryer. Failure
to follow
these instructions
can create electrical shock and/
or a fire hazard.
This appliance
MUST be properly
grounded.
Electrical shock can result if the dryer is not properly grounded.
Follow the instructions in this manual for proper grounding.
Do not use an extension
cord with this dryer.
Some extension cords are not designed to withstand the amounts
of electrical current this dryer utilizes and can melt, creating
electrical shock and/or fire hazard. Locate the dryer within reach
of the receptacle for the length power cord to be purchased,
allowing some slack in the cord. Refer to the pro-installation
requirements in this manual for the proper power cord to be
purchased.
A U.L. approved
strain relief must be installed
onto power
cord. If the strain relief is not attached, the cord can
be pulled out of the dryer and can be cut by any movement of the
cord, resulting in electrical shock.
Do not use an aluminum
wired receptacle with
a copper wiredpower
cord andplug (or vice versa). A chemical
reaction occurs between copper and aluminum and can cause
electrical shorts. The proper wiring and receptade
is a copper
wired power cord with a copper wired receptacle.
NOTE: Dryers operating on 208 volt power supply will have longer
drying times than operating on 240 volt power supply.
GROUNDING REQUIREMENTS
I
USA ELECTR/CDryer
1
Improper connection of the equipment grounding
conductor can result in a risk of electrical shock. Check with a
licensed electrician if you are in doubt asto whether the appliance
is properly grounded.
For a grounded,
cord-connected
dryer:
1. The dryer MUSTbe grounded. In the event of a malfunction
or breakdown, grounding will reduce the risk of electrical shock
by a path of least resistance for electrical current.
,
If your dryer is equipped with a power supply cord having an
equipment-grounding
conductor and a grounding plug, the
plug MUST be plugged into an appropriate, copper wired
receptacle
that is properly
installed
and grounded
in
accordance with all local codes and ordinances. If in doubt,
call a licensed electrician. Do not modify
plug provided
with the appliance.
-i
Canadian ELECTR/CDryer
j
Improper connection of the equipment grounding
conductor can result in a risk of electrical shock. Check with a
licensed electrician if you are in doubt as to whether the appliance
is properly grounded.
For a grounded, cord-connected dryer:
1. The dryer must be grounded. In the event of a malfunction or
breakdown, grounding will reduce the risk of electrical shock
by a path of least resistance for electrical current.
,
Since your dryer is equipped with a power supply cord having
an equipment-grounding conductor and a grounding plug, the
plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and
ordinances. If in doubt, call a licensed electrician.
Do not
modify plug provided
with the appliance.
ALL GASDryers
1. The dryer is equipped with a three-prong (grounding) plug
for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong
from the plug.
,
GAS CONNECTION
Remove the shipping cap from gas pipe at the rear of the
dryer.
NOTE: DO NOTconnect
the dryer to L.R gas service without
converting the gas valve. An L.Rconversion kit must be installed
by a qualified gas technician.
2.Connect a 1/2 inch (1.27 cm)I.D, semi-rigid or approved pipe
from gas supply line to the 3/8 inch (0.96 cm) pipe located on
the back of the dryer (see pages 6 and 7). Use a 1/2 inch to 3/
8 inch (1.27 cm to 0.96 cm) reducer for a connection. Apply
an approved thread sealer that is resistant to the corrosive
action of liquefied gases on all pipe connections.
3. Open the shutoff valve in the gas supply line to allow gas to
flow through pipe.
4. Test all connections by brushing on a soapy water solution.
NEVER test for gas leaks with an open flame.
For a permanently
connected dryer:
1. The dryer MUSTbe connected to a grounded metal, permanent
wiring system; or an equipment grounding conductor must be
run with the circuit conductors
and connected
to the
equipment-grounding
terminal or lead on the appliance.
11
VALVE OPEN /
GAS FLOW POSITION