Installation instructions, indoor Exhausting
CONNECTING
THE DRYER
TO HOUSE VENT
RIGID METAL TRANSITION
DUCT
* For best dxying perfk_rmance,
a rigid metal
transition
duct is recommended.
* Rigid metal
transitions
ducts reduce
the risk of crush-
ing and
kinking.
UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION
DUCT
* If rigid metal
duct cannot
be used, then
Ul,-listed
flexible
metal
(semi-rigid)
ducting
can be used (Kit
WX08X10077).
* Never
install
flexible
metal
duct in walls, ceilings,
floors
or other
enclosed
spaces.
* Total
length
of flexible
metal
duct should
not exceed
8
feet (2.4m).
* For many applications,
installing
elbows at both
the
diyer
and
the wall is highly
recommended
(see illustra-
tions below).
Elbows
allow the d_yer to sit close to the
wall without
kinking
and or crushing
the transition
duct, maximizing
d,ying
perf_rmance.
* Avoid resting
the duct on sharp
objects.
UL-LISTED FLEXIBLEMETAL (FOIL-TYPE) TRANSITION DUCT
* In special installations,
it may be necessai T to connect
the d_Ter to the hot_se vent using a flexible metal (fkfil-
type) dt_ct. A UL-listed flexible metal (fkfil-type)dt_ct
may be t]sed ONIX in installations
where rigid metal or
flexible metal (semi-rigid)
ducfing cannot be used AND
where a 4" diameter
can be maintained
throughout
the
entire length of the transition
dt_ct.
* In Canada and the United States, only the flexible
metal (f_il-type) ducts that comply with the "Outline f_r
Clothes D_yer Transition
Duct Subject 2158A" shall be
used.
* Never install flexible metal duct in walls, ceilings, floors
or other enclosed spaces.
* Total length of flexible metal duct should not exceed 8
feet (2.4m).
* Avoid resting the duct on sharp objects.
* For best drying perf_rmance:
]. Slide
one end of the duct over
the clothes
dryer
outlet
pipe.
2. Secure
the
duct
with
a clamp.
3. With
the d_yer in its permanent
position,
extend
the
duct
to its fifll length.
Allow
9" of duct
to overlap
the
exhaust
pipe.
Cut offand
remove
excess
duct.
Kee I)
the duct
as straight
as possible
t_r maximum
airflow.
4. Secure the duct to the exhaust pipe with the other
clamp.
ELBOW HIGHLY
RECOMMENDED
__
SHIGHLY I
MENDED
ALCOVE OR CLOSET iNSTALLATiON
* If yore" dlTer is approved
for installation
in an alcove or
closet, it will be stated on a label on the dryer back.
° The dryer MUST be vented to the outdoors.
See the
EXHAUST
INFORMATION
sections 3 & 4.
* Minimmn
clearance
between duer
cabinet and adjacent
walls or other surfaces is:
0 in. either side
3 in. Kont and rear
* Minimmn
vertical space from floor to overhead
cabinets,
ceiling, etc. is 52 in.
* Closet doors must be iouvered or othetwvise ventilated and
must contain a minimum
of 60 sq. in. of open area equally
distributed.
If the closet contains both a washer and a
duet, doors must contain a minimum
of 120 sq. in. of open
area equally distributed.
BATHROOM
OR BEDROOM
INSTALLATION
* The dryerMU ST be vented to the outdoors.
See
EXHAUST INFORN_TION
section 3 & 4.
* The installation
must conform
with local codes or, in the
absence of local codes, with the NATIONAL
ELECTRI-
CAL CODE, ANSI/NFPA
NO. 70.
5
FSq MOBILE OR MANUFACTURED
HOME INSTALLATION
° Installation
must conform
to the MANUFACTURED
HOME CONSTRUCTION
& SAFETY STANDARD,
TITLE 24, PART 32-80 or, when such standard
is not
applicable,
with %MERICAN NATIONAL STANDARD
FOR MOBILE HOME, ANSI/NFPA
NO. 501B.
° The dryer MU ST be vented to the outdoors
with the
termination
securely fastened to the mobile home
structure.
(See EXHAUST
INFORMATION
section 3 & 4.)
* The vent MUST NOT be terminated
beneath
a mobile or
mam_factured
home.
* The vent duct material MU ST BE METAL.
* Do not use sheet metal screws or other fastening
devices
which extend into the interior
of the exhaust vent.
* See section 2 for electrical connection
information.