Installation
Instructions
HOOD EXHAUST
NOTE: Read these next two pages only if you plan to vent your exhaust to the outside.
If you plan to recirculate
the air back into the room, proceed to page 6.
OUTSIDE TOP EXHAUST (EXAMPLE ONLY)
The following chart describes an example of one possible
ductwork installation.
EQUIVALENT
NUMBER
EQUIVALENT
DUCTPIECES
LENGTH
x
USED
=
LENGTH
RoofCap
12 Ft.Straight Duct
(6" Round)
24 Ft.
12 Ft.
24 Ft.
12 Ft.
Rectangular-to-Round
5 Ft.
x
(1)
=
5 Ft.
TransitionAdaptor*
Equivalent l engthsof duct piecesare basedon actualtests and
reflect requirements for goodventing performance with anyvent hood.
Total Length
=
41 Ft.
*IMPORTANT: If a rectangular-to-round
transition adaptor is used, the bottom corners of the damper will
have to be cut to fit, using the tin snips, in order to allow free movement of the dumper.
OUTSIDE BACK EXHAUST {EXAMPLE ONLY}
The following chart describes an example of one possible
ductwork installation.
EQUIVALENT
NUMBER
EQUIVALENT
LENGTH*
x
USED
=
LENGTH
DUCT PIECES
Wall Cap
3 Ft.Straight Duct
3W' x 10" Rectangular)
g0° Elbow
40 Ft.
x
(1)
3 Ft.
x
(1)
10 Ft.
x
(2)
Equivalent l engthsof duct piecesare basedon actual tests and
reflect requirements for goodventing performance with anyvent hood.
Total Length
40 Ft.
3 Ft.
20 Ft.
63 Ft.
NOTE: For back exhaust, core should be token to align exhaust with space between studs, or wall should be prepared
at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.