  • Page 1 Installation Instructions Downdraft Vent Systems PVB94 PVB98 ZVB30 ZVB36 J31-i0728-3 07-11 GE...
  • Page 2 Safety Information BEFORE YOU BEGIN WA RN I N G: TO REDUCE THE RISK Read these instructions completely and carefully. OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING. •IM PORTANT- Sove these instructions Use this unit only in the manner intended by for local inspector's the manufacturer.
  • Page 3: Table Of Contents

    Design Information CONTENTS Design Information Ductwork Product Dimensions ..............Duct Fittings ................Accessories .................. Installation Instructions Advance Planning ............... 4, 5 Step 1, Install Downdraft Vent ......... Installation Preparation Step 2, Install the Ductwork ..........Clearances ................6, 7 Step 3, Install Remote Switch ........... Parts Supplied ................
  • Page 4: Advance Planning

    The installation of these downdraft vents with 3. Review the cabinet illustration. Check to be sure any GE or Monogram cooktop requires careful the interior cabinet depth will house the cooktop consideration. Before you begin, review the burner box, the vent and the cutout clearance...
  • Page 5: Clearances

    , Refer to your specific cooktop instollation the vent's two-foot-long power cord. instruction for appropriate clearances. , The vent and a GE or Monogram gas cooktop , Installotion must conform with Iocol codes. combination can operate from the some 120-volt standard duplex outlet.
  • Page 6 Installation Preparation CUTOUTS AND CLEARANCES , Measure carefully when cutting the countertop. , Refer to cooktop installation instructions to be sure that models fit into the base cabinets being , Make sure sides of the opening are parallel and used. rear and front cuts are exactly perpendicular (right angles) to the sides.
  • Page 7: Parts Supplied

    Installation Preparation PARTS SUPPLIED TOOLS AND MATERIALS REQUIRED Open the carton and remove parts package. , Large flat-blade screwdriver Check contents to be sure all pieces are present. . Jigsaw , Carpenter's square . Ductwork to suit the installation . Level 2 Stabilizing Brackets REMOVE PACKAGING With Screws...
  • Page 8: Power Supply

    , Gas Cooktops with a three-prong (grounding) plug which mates If this vent is installed in combination with a GE with a standard three-prong grounding wall or Monogram gas cooktop, it may operate from receptacle to minimize the possibility of electric the same duplex outlet.
  • Page 9: Venting Options

    Installation Preparation VENTING OPTIONS Loosen Screws to Adjust 3-1/2" to , The downdraft vent is shipped with the Left or Right discharge outlet pointing straight down and can be changed to the left or right side. , The blower outlet is sized for 3-1/4" x 10" and can be transitioned to 6"...
  • Page 10: Duct Fittings

    *Actual length of straight duct plus duct fitting equivalent. Equivalent length of duct pieces is based heating equipment on actual tests conducted by GE Evaluation Engineering manufacturer's and reflect requirements for good venting performance guidelines and safety with any downdraft cooktop.
  • Page 11: Installation Instructions

    Installation Instructions [_ INSTALL DOWNDRAFT VENT [_]INSTALL DUCTWORK (_) One stabilizing bracket must be installed on , The downdraft blower system is designed for use each side of the downdraft vent. with 3-1/4" x 10" ductwork. It can be transitioned to 6"...
  • Page 12: Step 3, Install Remote Switch

    Installation Instructions [-_ INSTALL REMOTE SWITCH AWARNING: SHOCK HAZARD Connect Remote Switch to Remote Harness Disconnect electrical power from unit before , Thread the remote harness through the 1/2"-dia. beginning switch installation. Failure to do so could hole and attach the harness connector to the result in personal injury or damage to the electrical...
  • Page 13: Step 4, Connect Power

    Installation Instructions F41CONNECT POWER Plug power cord into properly grounded receptacle. rs] INSTALL FILTERS, CHECK OPERATION , Press the ON/OFF pad on the control to raise the vent. , Slip fingers into the vent holes. Lift the vent straight up and pull forward. Retainers Filter Tabs , Slide filter into the retainers and close the vent.
  • Page 14 Notes...
  • Page 15 Notes...
  • Page 16 NOTE:While performing installations described in this book, safety glasses or goggles should be worn. NOTE:Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and specifications are subject to change without notice. GE Consumer & Industrial Appliances General Electric Company J31-i0728-3...