GE Monogram ZVB36 Installation Instructions Manual
GE Monogram ZVB36 Installation Instructions Manual

GE Monogram ZVB36 Installation Instructions Manual

Downdraft vent systems
Hide thumbs Also See for Monogram ZVB36:

Advertisement

Quick Links

®
GE Monogram
Downdraft Vent
Systems
Installation
Instructions
36" Wide Models:
ZVB36
30" Wide Models:
ZVB30

Advertisement

Table of Contents
loading

Summary of Contents for GE Monogram ZVB36

  • Page 1 ® GE Monogram Downdraft Vent Systems Installation Instructions 36" Wide Models: ZVB36 30" Wide Models: ZVB30...
  • Page 2: Table Of Contents

    If you have a question concerning the installa- • Do not attempt to repair or replace any part tion of this product, call the GE Answer of the downdraft system unless it is specifi- Center® Consumer Information Ser vice at cally recommended in this book.
  • Page 3: Models Available

    Design Information Downdraf t Vent Systems These downdraft vents systems can be Models retracted when not in use. Available ZVB36 ZVB30 36" Wide Downdraft Vent 30" Wide Downdraft Vent in white, black and stainless steel in white, black and stainless steel •...
  • Page 4: Advance Planning

    Design Information Downdraf t Vent Systems The installation of these downdraft vents with Before you begin you must: Advance any Monogram cooktop requires careful 1. Review countertop dimension illustrations Planning consideration. For accurate planning, this to be sure you will have enough flat book provides individual dimension drawings countertop surface.
  • Page 5 Design Information Downdraf t Vent Systems Clearances • If cabinetry is used above the cooking Advance • The downdraft system with blower, motor surface: Planning and ductwork will occupy the cabinet below – Use cabinets no more than 13" deep. the countertop and cooktop.
  • Page 6: Installation Preparation

    Installation Preparation Downdraf t Vent Systems • Measure carefully when cutting the • Identify the cutout illustration for the Cutouts and countertop. Make sure sides of the opening cooktop model you are installing. Clearances are parallel and rear and front cuts are –...
  • Page 7 Installation Preparation Downdraf t Vent Systems 36" ZEU36WM and 3/16" 3/16" 1/4" Overlap 34" Vent Cutout ZEU365 Cooktops with 36” Vent 1/8" Gap 2-1/2" 21-3/4" Cutout 22-5/8" Depth Total Flat Surface 19-1/4" Required 34-3/8" Cooktop Cooktop Area Cutout Cutout Depth 5/8"...
  • Page 8: Cutouts For Monogram Cooktops

    Installation Preparation Downdraf t Vent Systems ZGU651 and 36" 1/4" 1/4" ZEU650 Cooktops 1/4" Overlap 34" Vent Cutout and 36” Vent 1/8" Gap 2-9/16" 20-7/8" Cutout 21-7/8" Depth Total Flat Surface 18-5/16" Required 34-7/16" Cooktop Cutout Cooktop Area Cutout Depth 3/4"...
  • Page 9 Installation Preparation Downdraf t Vent Systems 36" Vent Width ZEU676 Cooktop 5/16" 5/16" 1/4" Overlap 34" Vent Cutout and 36” Vent 1/8" Gap 2-1/4" 22-1/8" CAUTION: This Cutout 22-3/4" installation requires Total Flat Depth Surface and extra deep 19-7/8" Required 34-5/8"...
  • Page 10: Clearances

    Installation Preparation Downdraf t Vent Systems Caution: Wall coverings, Clearances countertops and cabinets should withstand 200° heat generated by any cooktop. Gas - 8-13/16" min. Electric - 2" Clearance to Sidewall 13" 13" Max. Max. 30" 30" Min. 18" Min. 18" Min.
  • Page 11: Remove Packaging

    Installation Preparation Downdraf t Vent Systems • Remove the shipping materials and the Remove Plastic Ties carton, set carton aside. The carton can be Packaging used as a pad when changing or adjusting vent direction. • Remove the plastic ties on both ends at the top of the vent.
  • Page 12: Venting Options

    Installation Preparation Downdraf t Vent Systems Loosen Screws Venting to Adjust Blower Left Options to Right Location Inside the Blower Discharge Loosen Screws to Rotate 30° to Left or 30° to Right 30° Rotation Left or Right Side to side adjustments: •...
  • Page 13 Installation Preparation Downdraf t Vent Systems • A left or right 90° direction adjustment To locate the ductwork holes in the cabinet Venting should be performed before dropping into floor or side walls: Options the countertop opening. • Temporarily, place vent into the countertop •...
  • Page 14: Ductwork

    * Actual length of straight duct plus duct fitting standards such as those equivalent. Equivalent length of duct pieces are based published by NFPA on actual tests conducted by GE Evaluation Engineer- ing and reflect requirements for good venting and ASHRAE. performance with any downdraft cooktop.
  • Page 15: Installation

    Installation Downdraf t Vent Systems Optional Method Step Secure to Cabinet Side With Top Screw on Case Install Or Use Second Screw Preferred Method Secure the Upper Downdraft Brackets With Screws Located on the side of Vent Case and Attach to Back Wall of Cabinet Secure the Lower Brackets to Blower Housing...
  • Page 16: Step 3, Install Raise/Lower Switch

    Installation Downdraf t Vent Systems Determine the location for the RAISE/ LOWER switch. The wiring lead is 72" long. Step • Drill a 1/8" hole into the desired location. Trim – If switch is mounted into a tile surface, drill Install the hole between tiles.
  • Page 17: Step 4, Connect Power

    Installation Downdraf t Vent Systems • Plug power cord into properly grounded Step receptacle. Connect Power To raise the vent, press the RAISE/LOWER switch. Step – On 30" models, the switch is located on the top right side of the vent. Install Filters, –...
  • Page 18: Jxrb57 Kit For Indoor Remote Blower Locations

    JXRB57 Kit For Indoor Remote Blower Locations Tools and Materials required: • Pencil • Measuring tape • Drill with appropriate bits • Nut driver • Junction box • Wire nuts • Safety glasses • 3-1/4" x 10" to 6" round transition. •...
  • Page 19 JXRB57 Kit For Indoor Remote Blower Locations Important: Save any • Remove the 4 nuts holding the blower to the Step unused parts. If the mounting plate. One nut is hidden inside appliance is relocated at the outlet. Remove blower. a later time, parts may be •...
  • Page 20 JXRB57 Kit For Indoor Remote Blower Locations Step Downdraft Connect Ductwork Duct Adapter Outlet Cover • The downdraft plenum can discharge from • Connect the plenum to the ductwork. A either the right or left side. Select the side transition is required to connect the 3-1/4" that provides the best alignment to x 10"...
  • Page 21: Jxbc57 Kit For Outdoor Remote Blower Locations

    JXBC57 Kit For Outdoor Remote Blower Locations Materials Required (not supplied) • Approved liquid tight service connections for use between the wire compartment on the base and inside the structure. • 7 wire nuts or other approved connectors. • Six 5/16" dia. fasteners compatible with the type of material the base is being fastened to.
  • Page 22 JXBC57 Kit For Outdoor Remote Blower Locations • The base is designed to be mounted to studs 16" 6 Holes For 5/16 on 16" centers. Use the dinensions shown to 6-11/16" Step Fastners determine the location of the ducting and wiring through the wall.
  • Page 23 JXBC57 Kit For Outdoor Remote Blower Locations • Remove the 4 nuts holding the blower to the mounting plate. One nut is hidden inside Step the outlet. Remove blower. • Remove the blower mounting plate. (continued) • Remove 2 screws along the bottom of the blower box which are visible once blower Hidden plate is removed.
  • Page 24 JXBC57 Kit For Outdoor Remote Blower Locations Plenum • Use electrical cable and connectors that Provided conform to local codes (14 gauge min. is Mounting recommended). Use a length to reach Step Screws between the vent and the blower/motor Blower Connect Wire location.
  • Page 25: Cleaning

    Stainless Steel Magic or a similar product. Stainless Steel Magic is available at Ace, True Value, Servistar, HWI and other leading stores. It is also available through GE Parts by calling 1-800-626-2002. Order part number WX10X15.
  • Page 26 Notes...
  • Page 27 Notes...
  • Page 28 NOTE: While performing installations described in this book, safety glasses or goggles should be worn. To obtain specific information concerning any ® Monogram product or service, call GE Answer Center consumer information service at 800.626.2000—any time, day or night. For Monogram local service in your area, call 1-800-444-1845.

This manual is also suitable for:

Monogram zvb30

Table of Contents