Connecting To 208 Volt Circuit - Bosch HBN 642A UC Installation Instructions Manual

Electric built-in single & double oven
Table of Contents

Advertisement

CONNECTING
TO 208 V CIRCUIT
The
ovens
are pre-wired
for connection
to 240
volt, 60 Hertz supply.
If connecting
to a 208 volt,
60 Hz. supply
a jumper
must be used across, two
terminals.
For the double
oven
models
ther'e are
two jumpers,
one for the upper
oven and one for
the lower oven. For the single
ovens there is one
jumper.
Please
refer
to figures
below
for placement
of
jumper for 208 volt, 60 hertz connection.
To connect to 208 volt circuit:
1
Remove the access panel(s) lQcated on the
back of the oven(s).
.
3.
Loosen the first and second screws in the ter-
minal block as shown in applicable
figure
above.
Place the metal jumper
between
the first
and second screws and tighten screws
to
hold jumper
in place.
4.
Replace
access panel(s).
Placing of jumper for single oven
or upper oven of double oven,
for connection to 208 volt, 60 Hz.
B_om
Jumper
JL_nper
After
Placing of jumper for lower oven
of double oven, for connection to
208 volt, 60 Hz.
Before
Jumper
Jumper
After