Section 3 Modbus Protocol and 2100 Output
Register Number(s)
Table 3-2 Modbus ASCII Address 2 +(N - 1) Register Definitions
Register Number(s)
1-4
5-23
a
24
b
25
c
26
d
27
28
29
30
40,41
42
43-48
55,56
57
58-63
70,71
72
73-78
85,86
87
88-93
3-6
The Modbus registers are assigned within 30 seconds after the
2100 module is powered up. To conserve power for the users who
do not use Modbus communications, no Modbus registers will be
updated with sensor readings until a Modbus master communi-
cates with the 2100 module.
The register definitions for the Site Information device (Modbus
ASCII address 1) are in Table 3-1:
Table 3-1 Modbus ASCII Address 1 Register Definitions
1
Number of module (N) (1-4)
2-20
Site name
The register definitions for the individual modules (Modbus
ASCII addresses 2 + (N - 1)) are in Table 3-2:
Name
Model number
Module name
Identify module
Take reading flag
Update interval
Active flag 1
Active flag 2
Active flag 3
Active flag 4
Level
e
Level status code
Level time record
Velocity
Velocity status code
Velocity time record
Flow
Flow status code
Flow time record
Flow 1
Flow 1 status code
Flow 1 time record
Name
Data type
16 bit integer
38-byte string
Data Type
8-byte string
38-byte string
16 bit integer
16 bit integer
16 bit integer
16 bit field
16 bit field
16 bit field
16 bit field
4-byte float
16-bit integer
f
Time
4-byte float
16-bit integer
Time
4-byte float
Cubic Meters/sec
16-bit integer
Time
4-byte float
Cubic Meters/sec
16-bit integer
Time
Units
Read/Write
None
Read
None
Read
Units
Read/Write
None
Read
None
Read
None
Read/Write
None
Read/Write
Seconds
Read/Write
None
Read
None
Read
None
Read
None
Read
Meters
Read
Read
Read
Meters/second
Read
Read
Read
Read
Read
Read
Read
Read
Read