27 IN. (69 CM) GAS DRYER
INSTALLATION INSTRUCTIONS
INSTRUCCIONES DE INSTALACION PARA LA
SECADOI::LA A GAS DE 27 PULG. (69 CM)
Table of Contents / |ndice
DRYER SAFETY ................................................
I
INSTALLATION
INSTRUCTIONS
.................... 2
Tools and Parts ..............................................
2
Location Requirements
................................. 3
Electrical Requirements ................................. 4
Gas Supply Requirements ............................. 4
Venting Requirements
................................... 5
Plan Vent System ...........................................
6
Install Vent System ........................................
8
Install Leveling Legs ....................................... 8
Level Dryer .....................................................
8
Make Gas Connection ................................... 9
Connect Vent .................................................
9
Complete Installation ..................................... 9
SERVICE NUMBERS ................. BACK COVER
SEGURIDAD DE LA SECADORA ............................
11
INSTRUCCIONES
DE INSTALACION
.................... 12
Herramientas y piezae ..........................
12
Requisitos de Iocalizaci6n
....................................
12
Requisitos el_ctricos .............................................
14
Requisitos del suministro de gas .......................... 14
Requisitos de ventilaci6n ......................................
16
Planificaci6n
del eistema de ventilaci6n ............... 16
Instalaci6n det sistema de ventilaci6n .................. 18
Instalaci6n de tas patas niveladoras ..................... 18
Nivetaci6n de la secadora .....................................
lg
Conexi6n del suministro de gas ............................ 19
Conexi6n del ducto de escape .............................
lg
Complete la instalaci6n .........................................
lg
NOMEROS DE SERVICIO ........... CONTRAPORTADA
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided
many
important
safety messages
in this manual
and on your appliance.
Always
read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions,
You can be killed or seriously injured if you don't follow
instructions,
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
When discarding or storing your old clothes dryer, remove the door.
SAVE THESE INSTRUCTIONS
3979977

Advertisement

loading

Summary of Contents for Kenmore 27 IN. (69 CM)

  • Page 1 27 IN. (69 CM) GAS DRYER INSTALLATION INSTRUCTIONS INSTRUCCIONES DE INSTALACION PARA LA SECADOI::LA A GAS DE 27 PULG. (69 CM) Table of Contents / |ndice DRYER SAFETY ..........SEGURIDAD DE LA SECADORA ......INSTALLATION INSTRUCTIONS ....2 INSTRUCCIONES DE INSTALACION ....
  • Page 2 WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, or to prevent property damage, personal injury, or death. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 3 Minimum installation spacing for recessed area or closet _ '_/_,_,_,_:_'°_, _,_::;: _, _}_S installation The dimensions shown following are for the minimum spacing allowed. • Additional spacing should be considered for ease of installation and servicing. Additional clearances might be required for wall, door and floor moldings.
  • Page 4 Electrical Shock Hazard Explosion Hazard Plug into a grounded 3 prong outlet. Use a new AGA or CSA approved gas supply line. Install a shut-off valve. Do not remove ground prong. Securely tighten all gas connections. Do not use an adapter. Do not use an extension cord.
  • Page 5 Gas Supply Line: Burner Input Requirements: • 1/2in. IPS pipe is recommended. Elevations up to 10,000 feet (3,048 meters): • The design of this dryer is certified by CSA International for • % in. approved tubing is acceptable for lengths under 20 ft use at altitudes up to 16,000 ft (3,048 m) above sea level at (6.1 m) if local codes and gas supplier permit.
  • Page 6 Use clamps to seal all joints. Exhaust vent must not be Optional exhaust installations connected or secured with screws or other fastening devices This dryer can be converted to exhaust out the right side, left which extend into the interior of the duct. Do not use duct side, or through the bottom.
  • Page 7 NOTE: The following kits for close clearance alternate Recommended hood styles are shown here. installations are available for purchase. Call 1-80O-4-MY-ROME (1-800-469-4663). • Over-The-Top Installation: Part Number 26-49900 • Periscope Installation (For use with dryer vent to wall vent mismatch): Part Number 26-49901 - Less than 5 in.
  • Page 8 Place a carton corner post under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. 1. (Optional) Put on safety glasses and gloves. Leave enough room to connect the exhaust vent.
  • Page 9 1o Remove the red cap from the gas pipe. Move the dryer close 1. Check to be sure all parts are now installed. If there is an to its final position. extra part, go back through the steps to see which step was skipped.
  • Page 11 INSTRUCCIONES DE INSTALACION PARA LA SECADORA A GAS 27 PULG. (69 CM) SEGURIDAD DE LA SECADORA Su seguridad y la seguridad de los demds es muy importante. Hemos incluido muchos mensajes importantes de seguridad en este manual yen su electrodomestico. Lea y obedezca siempre todos los mensajes de seguridad.
  • Page 12 INSTRUCCIONES DE INSTALACION Verifique si tiene todo Io necesario para una instalaci6n correcta. La instalaci6n adecuada es responsabilidad suya. Llave para tubos de 8 6 • Llave para tuercas de _/4 10 pulg. de pulg. o Ilave de cubo Llave de tuercas •...
  • Page 13 Espacios para la Instalacibn • Tambien se debe considerar espacio adicional para otro electrodomestico que le acompafie. La ubicaci6n debe ser Io suficientemente grande para poder abrir completamente la puerta de la secadora. 23" Dimensiones de la secadora _eet 14" (310 ¢m=) •...
  • Page 14 _,_ _'>_ _}_ + i_ _i,_y_'_ , ¸ _ _}_ + Peligro de Explosi6n Peligro de Choque El_ctrico Usa una inea de suministro de gas nueva con Conecte a un coatacto de pared de conexi6n a tierra de aprobaci6n AGA o CSA. 3 terminales.
  • Page 15 La linea de suministro de gas: • Las longitudes superiores a los 20 pies (6,1 m) deberan usar tuberias mas largas y un accesorio adaptador de tama_o • Se recomienda un tubo IPS de 1/2 de pulg. distinto. • Si los c6digos locales y el proveedor de gas Io permiten, es •...
  • Page 16 Se recomienda el ducto de escape de metal rigido para evitar que se aplaste o se tuerza. El ducto de escape de metal flexible debe extenderse y sostenerse pot completo cuando la secadora este en su ubicaci6n final. Quite el exceso del conducto de metal flexible para evitar que se doble y se tuerza, Io cual podria dar lugar a una reducci6n del flujo de aire y un funcionamiento insuficiente.
  • Page 17 Instalaciones opcionales de escape NOTA: Se pueden adquirir los siguientes juegos para instalaciones alternas en espacios limitados. Llame al El sistema de ventilaci6n de esta secadora puede modificarse 1-800-4-MY-HOME _ (1-800-469-4663). hacia el lado derecho, el lado izquierdo o por la parte inferior. Instalaci6n en la parte superior: Pieza n0mero 26-49900 Instalaci6n de periscopio...
  • Page 18 Los estilos recomendados de capotas de ventilaci6n se ilustran aqui. I,<_ _ 1. (Opcional) P6ngase lentes de seguridad y guantes. Instale la capota de ventilaci6n. Emplee una masilla de calafateo para sellar la abertura de la pared externa alrededor de la capota de ventilaci6n. 3.
  • Page 19 Para uso en casas rodantes 3. Abra la valvula de cierre del suministro. La valvula est,. abierta cuando la manija esta paralela al tubo de gas. Las secadoras a gas deben ser aseguradas al piso con firmeza. 1. V4tvuta cerrada 2.
  • Page 20 Your Home For repair-in your home-of all major brand appliances, lawn and garden equipment, .or heating and cooling systems, no matter who made zt, no matter who sold ztt For,the replacement parts, accessories and owner s manuals that you need to do-it-yourself. For Sears professional installation of home appliances and items like garage door openers and water heaters.