27" (69 CM) ELECTRIC DRYER
INSTALLATION INSTRUCTIONS
INSTRUCCIONES DE INSTALACION PARA LA
SECADORA ELI_CTRICA DE 27" (69 CM)
Table of Contents/indice
DRYER SAFETY ...............................................
1
INSTALLATION
INSTRUCTIONS .................... 2
Tools and Parts .............................................
2
Location Requirements
................................
2
Electrical Requirements ................................
3
Electrical Connection ....................................
5
Venting Requirements .................................
10
Plan Vent System ........................................
11
Install Vent System ......................................
12
Install Leveling Legs ....................................
12
Connect Vent ...............................................
13
Level Dryer ..................................................
13
Complete Installation ..................................
13
SERVICE NUMBERS ................. BACK COVER
SEGURIDAD
DE LA SECADORA .................. 14
DE INSTALACION ........... 14
Herramientas y piezas ................................. 14
Requisitos de ubicacion .............................. 15
Requisitos el_ctricos .................................... 16
Conexi6n el_ctrica .......................................
18
Requisitos de ventilacion ............................. 23
Instalacion del sistema de ventilaci6n ......... 26
Instalaci6n de las patas niveladoras ............ 26
Conexi6n del ducto de escape .................... 26
Nivelacion de la secadora ............................ 26
Complete la instalaci6n ............................... 27
NUMEROS DE SERVICIO CONTRAPORTADA
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided
many important
safety
messages
in this manual
and on your appliance.
Always
read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
8576656

Advertisement

Table of Contents
loading

Summary of Contents for Kenmore 27" (69 CM)

  • Page 1: Table Of Contents

    27" (69 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS INSTRUCCIONES DE INSTALACION PARA LA SECADORA ELI_CTRICA DE 27" (69 CM) Table of Contents/indice DRYER SAFETY ..........SEGURIDAD DE LA SECADORA ....14 INSTRUCCIONES DE INSTALACION ... 14 INSTALLATION INSTRUCTIONS ....2 Tools and Parts ..........Herramientas y piezas .........
  • Page 2: Instructions

    INSTALLATION INSTRUCTIONS Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Flat-blade screwdriver Tin snips(new vent • installations) #2 Phillips screwdriver Level • Adjustable wrench that opens to 1" (2.5 cm) or Vent clamps •...
  • Page 3: Electrical Connection

    Installation Clearances Mobile Home - Additional Installation Requirements The location must be large enough to allow the dryer door to This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home open fully. Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction Dryer Dimensions and Safety, Title 24, HUD Part 280).
  • Page 4 If using a power s upply cord: If connecting by direct wire: Use a ULlisted power supply c ordkitmarked forusewith Power supply cable must match power supply (4-wire or 3-wire) clothes d ryers. The kitshould contain: and be: [] AULlisted 30-amp p ower s upply c ord, r ated Flexible armored cable or nonmetallic sheathed copper cable 120/240 voltminimum.
  • Page 5 (}<_" ®C_:O Direct Wire Power Supply Cord Fire Hazard Fire Hazard Use 10 gauge solid copper wire. Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Use a UL listed strain relief. Disconnect power before making electrical connections. Disconnect power before making electrical connections.
  • Page 6 Put power supply cord through the strain relief. Be sure Electrical Connection Options that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with If your home has: And you will be Go to Section: the dryer cabinet and be in a horizontal position.
  • Page 7: Venting Requirements

    Remove center silver-colored terminal block screw. 4-wire connection: Direct Wire Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire IMPORTANT: A 4-wire connection is required for mobile homes (white or center wire) of power supply cord under center, and where local codes do not permit the use of 3 wire silver-colored terminal block screw.
  • Page 8 3. Connect ground wire (green or bare) of direct wire cable to 2. Connect neutral wire (white or center wire) of power supply cord to the center, silver-colored terminal screw of the external ground conductor screw. Tighten screw. terminal block. Tighten screw. A.
  • Page 9 Loosen or remove center silver-colored terminal block screw. Optional 3-wire connection Place the hooked end of the neutral wire (white or center wire) of direct wire cable under the center screw of terminal block Use for direct wire or power supply cord where local codes (hook facing right).
  • Page 10 • Remove excess flexible m etal vent t oavoid sagging and kinking t hatmay result i nreduced a irflow andpoor performance. • Donotinstall flexible m etal vent i nenclosed walls, ceilings or floors. Elbows 45 ° elbows provide better airflow than 90 ° elbows. Fire Hazard Use a heavy metal vent.
  • Page 11 ..Alternate installations for close clearances Choose your exhaust installation type Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Recommended exhaust installations Refer to the manufacturer's instructions. Typical installations vent the dryer from the rear of the dryer. Other installations are possible.
  • Page 12: Connect Vent

    Determine vent path 1. Install exhaust hood. Use caulking compound to seal exterior • Select the route that will provide the straightest and most wall opening around exhaust hood. direct path outdoors. 2. Connect vent to exhaust hood. Vent must fit inside exhaust •...
  • Page 13: Level Dryer

    1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in 1. Check that all parts are now installed. If there is an extra part, dryer. If connecting to existing vent, make sure the vent is go back through the steps to see which step was skipped. clean.
  • Page 14: De La Secadora

    INSTRUCCIONES DE INSTALACION PARA LA SECADORA ELI CTRICA DE 27" (69 CM) SEGURIDAD DE LA SECADORA Su seguridad y la seguridad de los demas es muy importante. Hemos incluido muchos mensajes importantes de seguridad en este manual yen su electrodomestico. Lea y obedezca siempre todos los mensajes de seguridad.
  • Page 15: Requisitos El_Ctricos

    No ponga a funcionar su secadora en las temperaturas inferiores a 45°F (7°C). A temperaturas inferiores, es posible que la secadora no se apague al final de un ciclo automatico. tiempos de secado pueden prolongarse. No debe instalarse ni guardarse la secadora en un Area en donde pueda estar expuesta al agua y/o a la intemperie.
  • Page 16: Conexi6N El_Ctrica

    Espacio para la instalaci6n en un lugar empotrado o en un cl6set So recomiendan las siguientes medidas de espacio para esta secadora. Esta secadora ha sido puesta a prueba para espacios Usted es responsable de de 0" (0 cm) on los costados y on la parte posterior. El espacio •...
  • Page 17 Si hace la conexi6n con cableado directo: Si emplea un cable de suministro el_ctrico: Use un juego aprobado de UL para cable de suministro electrico El cable de suministro electrico debe ser igual al suministro que este marcado para ser usado en secadoras de ropa. El juego electrico (de 4 alambres o de 3 alambres) y debe ser: debera contener: Cable blindado flexible o cable de cobre forrado no metalico...
  • Page 18 Cable de suministro el_ctrico Cableado directo Peligro de Incendio Peligro de Incendio Utilice alambres de cobre solide de ancho 10. Use un cable de suministro electrico nuevo de 30 amperes que este en la lista de UL. Use un protector de cables que este en la lista de UL. Use un protector de cables que este en la lista de UL.
  • Page 19 Haga pasar el cable de suministro electrico a traves del 4. Ahora termine la instalaci6n siguiendo las instrucciones para protector de cables. AsegQrese de que el aislamiento de el tipo de su conexidn electrica: alambre del cable de suministro electrico este dentro del Alambre de 4 hilos (se recomienda) protector de cables.
  • Page 20: Requisitos De Ventilacion

    Saque el tornillo central de color plateado del bloque de terminal. Conexi6n de 4 hilos: Cable directo Saque el hilo neutro de puesta a tierra del aparato del tornillo IMPORTANTE: Se necesita una conexi6n de 4 hilos para las conductor de tierra externo.
  • Page 21 Conecte el hilo de tierra (verde o desnudo) del cable de 1. Afloje o saque el tornillo central de color plateado del bloque conexi6n directa al tornillo del conductor de tierra externo. de terminal. Apriete el tornillo. 2. Conecte el hilo neutro (hilo blanco o central) del cable de suministro electrico al tornillo central de color plateado del bloque de terminal.
  • Page 22 Afloje o saque el tornillo central de color plateado del bloque de terminal. Conexibn opcional de 3 hilos Coloque el extreme en forma de gancho del hilo neutro (hilo Use para cable directo o cable de suministro el_ctrico donde blanco o central) del cable de conexi6n directa debajo del los cbdigos locales no permitan la conexi6n del conductor de tornillo central del bloque de terminal (con el gancho mirando tierra del gabinete con el hilo neutro.
  • Page 23 Ducto de escape de metal rigido • Para un 6ptimo rendimiento de secado, se recomiendan ductos de escape de metal rigido. • Se recomienda el ducto de escape de metal rigido para evitar que se aplaste o se tuerza. Ducto de escape de metal flexible •...
  • Page 24 El estilo de capota de ventilaci6n angular (que se ilustra aqu0 Instalaciones opcionales de escape es aceptable. 4" (10,2 cm__ 21/2. • (6,4cm) • Una capota de ventilaci6n debe tapar el ducto de escape Peligro de Incendio para evitar el ingreso de roedores e insectos a la casa. Cubra los orificios de escape con uno de los juegos •...
  • Page 25 Instalaciones alternas para espacios limitados Determinacibn de la via del ducto de escape Los sistemas de ventilaci6n vienen en una amplia gama. Seleccione el tipo mas apropiado para su instalaci6n. A • Seleccione la vfa que proporcione el trayecto mas recto y continuaci6n se ilustran dos tipos de instalaci6n para espacios directo al exterior.
  • Page 26: Planificaci6N Del Sistema De Ventilaci6N

    3. Examine las patas niveladoras. Localice la marca en forma de diamante. : ssc6s ..ms de vest sc o_ 1. Instale la capota de ventilaci6n. Emplee una masilla de calafateo para sellar la abertura de la pared externa alrededor de la capota de ventilaci6n.
  • Page 27 Com : e :e a ns aacon 1. Revise para cerciorarse de que todas las piezas esten Si la secadora no funciona, revise Io siguiente: instaladas. Si hay alguna pieza extra, vuelva a revisar todos • Que los controles esten fijados en una posici6n de los pasos para ver cual se omiti6.
  • Page 28 Your Home For repair-in your home-of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories owner's manuals that you need to do-it-yourself. For Sears professional installation of home appliances and items like garage door openers and water heaters.

This manual is also suitable for:

110.69822801