Haier HSU-09R04 Operation Manual

Split type room air conditioner
Hide thumbs Also See for HSU-09R04:

Advertisement

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HSU-09R04
HSU-12R04
HSU-18R04
HSU-24R04
Please read this operation manual before using the air conditioner.
No.0010552177

Advertisement

Table of Contents
loading

Summary of Contents for Haier HSU-09R04

  • Page 1: Operation Manual

    SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-09R04 HSU-12R04 HSU-18R04 HSU-24R04 Please read this operation manual before using the air conditioner. No.0010552177...
  • Page 2: Table Of Contents

    Contents Cautions Parts and functions Operation Maintenance Trouble shooting 5-12 13-15...
  • Page 3: Cautions

    10.The appliance must be installed on strong enough supporter. 11.The wiring diagram is attached inside the machine. 12.For model HSU-24R04, the breaker of the air conditioner should be an air gap contact. Such means for disconnection must be incorporation in the fixed wiring according to the wiring rules.
  • Page 4: Parts And Functions

    Timer mode indicator Power indicator Lights up when Timer operation Lights up when unit starts. is selected. HSU-09R04 HSU-12R04 Power indicator Lights up when unit starts. Test running switch(manual) Used only for test running in cooling when room temp. is below 16 Don't use it in normal operation.
  • Page 5: Outdoor Unit

    Parts and Functions Outdoor Unit CONNECTING PIPING AND ELECTRICAL WIRING INLET OUTLET HSU-09R04 HSU-12R04 HSU-18R04 HSU-24R04 DRAIN HOSE...
  • Page 6 Parts and Functions Operation ON/OFF MODE SWING SLEEP LOCK Clock set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press to set correct time.
  • Page 7 LOCK BRIEF INTRODUCTION TO HEALTH OPERATION The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
  • Page 8: Operation

    When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFFto turn off the unit when power resumes.
  • Page 9 Operation Auto run, Fan operation (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator on indoor unit lights up. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: AUTO COOL...
  • Page 10: Cool,Heat And Dry Operation

    Operation COOL,HEAT and DRY operation Recommendations: (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator on indoor unit lights up. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: AUTO COOL...
  • Page 11 Operation (5) Air flow direction adjustment After operation mode is selected, vertical flap will open automatically according to the mode. Referring to the Fig. COOL About 10 Up and down (Use remote controller) Press SWING button, vertical flap will move within the range shown in the Fig.
  • Page 12: Timer Operation

    Operation TIMER Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode.
  • Page 13 Operation TIMER ON-OFF TIMER ON-OFF (1)After unit start, select your desired operation mode Operation mode will be displayed on LCD. Power indicator on indoor unit lights up. (2) Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: TIMER ON TIMER OFF Select TIMER ON-OFF.
  • Page 14 More than 23 Less than 23 If an air conditioner is a model for both cooling and heating. Cooling when the room temperature at the start of operation is above 23 Heating when the room temperature at the start of operation is below 23...
  • Page 15 Operation Comfortable SLEEP Before going to bed at night, you can simply press the SLEEP button and unit will bring you a sound sleep in selected mode. In COOL mode One hour after SLEEP mode starts, temp. will become 1 C higher than temp.
  • Page 16: Maintenance

    Maintenance Different models have different appearance Cleaning of unit casing Cleaning of remote controller Cleaning of air filter 1.Open inlet grille by pulling it upward. 3.Clean the filter Use a vacuum cleaner to remove dust,or wash the filter with water. After washing, dry the filter completely in the shade.
  • Page 17 Maintenance Replacement of Air purifying Filter Open the Inlet grille Open the Inlet grille by pushing each ends of the Inlet grille upward.(use thumbs to push up) Detach the standard air grille Slide the knob slightly upward to release the filter, then withdraw it.
  • Page 18 Maintenance Better use of air conditioner Proper room temperature. Closing of doors and windows during operation Never fail to observe the followings Do not sprinkle water over the unit. Do not pull power plug. Cleaning of the air filter. Proper temperature Effective use of the timer.
  • Page 19: Trouble Shooting

    When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable.

This manual is also suitable for:

Hsu-12r04Hsu-18r04Hsu-24r04