GS700TP Smart Switch Software Administration Manual
–
Disable – Disable device logs.
–
Enable – Enable device logs.
2. Select either Enable or Disable as the Logging State in the provided field.
3. Click APPLY to update the device.
Log Filter
To configure log filters:
1. Click Monitoring > Logs > Log Filter. The Log Filter screen displays:
Figure 7-2
The Log Filter screen contains the following fields:
•
RAM Logs – Select the minimum message severity level to appear in the RAM Log. The
following are the available message severity levels:
–
Emergency – The highest warning level. If the device is down or not functioning
properly, an emergency log message is saved to the specified logging location.
–
Alert – The second highest warning level. An alert log is saved, if there is a serious
device malfunction; for example, all device features are down.
–
Critical – The third highest warning level. A critical log is saved if a critical device
malfunction occurs; for example, two device ports are not functioning, while the rest
of the device ports remain functional.
–
Error – A device error has occurred; for example, if a single port is offline.
–
Warning – The lowest level of a device warning. The device is functioning, but an
operational problem has occurred.
–
Notice – Provides device information.
Monitoring the Switch
v1.0, April 2008
7-3