INSPECTION

Frequency

The furnace should be inspected annually by a licensed
HVAC technician. Homeowners should perform frequent
visual inspections. Table 1 contains suggested inspections
and frequency of maintenance.

Venting System

• Existing vent pipes should be inspected and any corroded
sections must be replaced. Obstructions or blockage
must be removed by a licensed HVAC technician.
• Flue passageways, the vent system, and the burners
should be inspected and cleaned (if required) by a
licensed HVAC technician annually to ensure continued
safe operation.

Blower and Filter

is recommended that the blower compartment be
It
cleaned of dirt or lint that may have accumulated in the
compartment or on the blower and motor as part of the
annual inspection.
MAINTENANCE ITEM
Verify furnace area is free of combustible materials.
Verify combustion and ventilation air is not restricted.
Verify no signs of physical deterioration of the furnace.
Verify no obstructions or restrictions in vent or chimney.
Verify no holes or cracks in vent pipe.
Verify no corrosion in vent pipe.
Verify the horizontal vent pipes slope upwards away from furnace.
Verify burner fl ame.
Clean or replace fi lter(s).
Clean blower compartment.
Clean burner assembly.
Clean condensate collection and disposal system (if applicable).

TROUBLESHOOTING

If the furnace fails to operate check the following:
1. Is the thermostat operating properly?
2. Are the blower compartment door(s) in place?
3. Has the circuit breaker tripped or the control board
fuse burned open?
6

Air for Combustion

• For proper and safe operation, the furnace needs air for
combustion and ventilation. Do Not block or obstruct
air openings on the furnace, or any air openings where
the furnace may be installed, including any surrounding
spaces.
• Direct vent furnaces pull combustion air from the
outdoors and vent combustion products back outside.
Combustion air coming from the outside needs to be
clean of chemicals that can cause corrosion, such as
pool chlorinating products.

Air for Comfort

• Keep air fi lters cleaned. It is recommended that the
furnace air fi lter be checked at least once a month. Clean
or replace fi lter to maintain proper airfl ow and achieve
maximum effi ciency .
• Furniture and drapery should be arranged so that
the supply air registers and return grilles are not
obstructed.

Burner Operation

Perform the startup instructions on page 7. The igniter
should ignite the closest burner and the fl ames should
quickly carryover to the other burners. The fl ames should
be bright blue, with occasional yellow streaks.
BEGINNING OF
EACH HEATING
Table 1. Maintenance Table
4. Is the gas turned on at the manual shutoff?
5. Is the fi lter dirty or clogged?
If the furnace continues to not operate, contact a licensed
HVAC technician
FREQUENCY OF MAINTENANCE
END OF EACH
HEATING SEASON
SEASON
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
MONTHLY
X
X
X
X

Advertisement