SAFETY INFORMATION

WARNING:
The safety information listed throughout this
manual must be followed during the installation,
service, and operation of this furnace. Failure
to follow safety recommendations could result
in possible damage to the equipment, serious
per sonal injury, or death .

Air for Proper Combustion

WARNING:
Do not reduce the supply of fresh air to the
furnace. This could create the production of
excessive amounts of Carbon Monoxide - a
colorless, odorless gas that is a deadly poison
that could result in serious personal injury
or death. Do not block any openings that are
supplying fresh air to the room or closet the
furnace is in. If your furnace obtains its air
through a pipe to the outdoors, do not allow
the inlet of the pipe to become blocked.

Flammable Vapors

WARNING:
Do not place combustible materials on or against
the furnace cabinet or within 6 inches of the
vent pipe. Do not place combustible materials,
including gasoline or any other fl ammable
vapors and liquids, in the vicinity of the furnace.
A fi re or explosion may result causing property
damage, personal injury or loss of life. Failure to
follow the safety warnings exactly could result
in serious injury, death or property damage.

Venting System

WARNING:
It is imperative to maintain proper operation of
the venting system. Insuffi cient venting could
create the production of excessive amounts
of Carbon Monoxide - a colorless, odorless
gas that is a deadly poison that could result in
serious personal injury or death.

Gas Supply and Piping

This furnace does not have a pilot. It is equipped with an
ignition device which automatically lights the burner. DO
NOT try to light the burner by hand.
BEFORE OPERATING smell all around the furnace area
for gas. Be sure to smell next to the fl oor because some
gas is heavier than air and will settle to the fl oor.
WARNING:
All gas piping and shutoff valves must be
installed in compliance with local codes and
utility regulations by licensed installers. DO
NOT attempt to modify, or tap into existing
gas lines yourself. Fire or explosion may result
causing property damage, personal injury or
loss of life. Failure to follow the safety warnings
exactly could result in serious injury, death or
property damage.
WARNING:
The furnace was shipped from the factory
equipped to operate on natural gas. Conversion
to LP/propane gas must be performed by a
licensed HVAC technician using a factory
supplied conversion kit. Failure to use the
proper conversion kit can cause fi re, explosion,
property damage, carbon monoxide poisoning,
personal injury, or death.

Combustibles

WARNING:
Do not place combustible material on or
against the furnace cabinet or within 6 inches
of the vent pipe. Do not place combustible
materials, including gasoline and any other
fl ammable vapors and liquids, in the vicinity
of the furnace.
The furnace is designed to have certain clearances to
combustible items such as wood, paper, etc. Some types
of insulation are combustible. If your furnace is installed
in an attic, near unfi nished walls, or in other insulated
space, keep area surrounding the furnace free of insulating
material. Do not put insulation on your furnace.