Empire Comfort Systems DVP36DP31 Series Installation Instructions And Owner's Manual page 33

Direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

DVVK-4FV DIRECT VENT TERMINATION KIT
PRE-INSTALLATION INFORMATION:
Items Required For Installation:
Tools
Phillips Screwdriver
Hammer
Saw and/or saber saw
Level
Measuring Tape
Electric Drill and Bits
Pliers
Square
Tin Snips
Before You Start:
Plan your installation. Read these instructions and the fireplace
installation manual before installing unit and vent system. Set unit
in place and survey how best to vent the unit. After the vent con-
figuration has been decided, stretch the flex pipe components out,
then trim off what will not be needed.
Refer to the fireplace installation manual for information on vertical
venting requirements. The maximum length of vent when using
flex venting is 35 feet total. Contact your dealer or distributor for
information on flex vent extension kits that may be added to the
DVVK-4FV kit, in order to terminate up to 35 feet. Available exten-
sion kits include the DVEK-10 (10' Flex) or the DVEK-25 (25' Flex)
extension kits. The extension kits include connection hardware.
Installation of the Vertical Flex Termination Kit
WARNING
Ensure that the venting system exits the structure through
the roof and does not terminate less than 12 inches (305mm)
above the roof.
WARNING
Refer to your fireplace homeowner's manual for the minimum
and maximum venting requirement of your fireplace prior to in-
stallation. Failure to do so may cause a fire hazard.
WARNING
This flexible pipe termination kit is ONLY for vertical termina-
tions.
WARNING
Any horizontal run section must have a 1/4" rise for every one
foot of run towards the vent termination. Never allow the vent
pipe to run downward. This could cause high temperatures and
may present a fire hazard. This vertical kit may incorporate two
90 degree bends, but must terminate vertically.
31451-2-1013
Building Supplies
Framing Materials
Wall Finishing Materials
Caulking Material (Noncombustible)
Support Strap supplies
CAUTION
This flex vent kit can be installed either vertically or horizontally
off of Direct Vent Series fireplaces but must only terminate verti-
cally.
WARNING
Because of sharp edges, always use gloves when handling the
flex vent components.
CAUTION
Vent connections should overlap a minimum of 1" for proper
sealing.
CAUTION
Always stretch and secure venting with metal strapping secured
with nails (nails and strapping not supplied) to ensure that the
flex vent runs remain true.
INSTALLATION NOTE:
If space permits, it is generally easier to attach venting in the
top vent configuration.
Page 33

Advertisement

Table of Contents
loading

Table of Contents