VENTING FIREPLACE - TOP (continued)
MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH
THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE
ELBOW OFF TOP OF FIREPLACE
Positioning the Fireplace
FIREPLACE
HARD ELBOW DIMENSIONS
SERIES
"A"
DVP36DP
43-1/2"
(1105mm)
FIREPLACE
FLEX PIPE 90 DEGREE BEND
SERIES
"A"
DVP36DP
45"
(1143mm)
Determine the exact position of the appliance so the direct vent
termination will be centered (if possible) between two studs. This
will avoid any extra framing. All vent kit pipes should be assembled
on the unit after the unit is moved into the final position.
Cutting the Hole
After the fireplace has been positioned in its permanent location, the
hole through the exterior wall of the house can be cut. This hole must be
11" (280mm) high x 10" (254mm) wide with its center line determined
by the amount of vertical rise and horizontal run of the termination.
See Figure 27. When locating the hole it must be noted that the
bottom of the cap must be 12" (305mm) above the ground level,
and top of the cap must be no less than 18" (457mm) below a
combustible projection, and no closer than 9" (229mm) to any wall
running parallel to vent termination. See Figure 28.
Page 20
Figure 27
"B"
"C"
4-1/2"
6-1/2"
(114mm)
(165mm)
"B"
"C"
4-1/2"
6-1/2"
(114mm)
(165mm)
Figure 28