3.
Lift each of the image drum units out of the printer and
place them in a safe place away from direct sources of
heat and light.
The green image drum surface at the base of each
cartridge is very delicate and light sensitive. Do not
touch it and do not expose it to normal room light for
more than 5 minutes. If the drum unit needs to be out
of the printer for longer than this, please wrap the
cartridge inside a black plastic bag to keep it away
from light. Never expose the drum to direct sunlight
or very bright room lighting.
4.
Locate the two fasteners (5) at each side of the belt and
the lifting bar (6) at the front end.
5
6
5.
Turn the two fasteners 90° to the left. This will release the
belt from the printer chassis.
6.
Pull the lifting bar (6) upwards so that belt tilts up
towards the front, and withdraw the belt unit from the
printer.