6.3
T
ROUBLESHOOTING THE
Malfunction
No power.
38
T
READMILL
Probable Cause
ON / OFF switch is not in proper
position.
Power source is insufficient.
Line cord is damaged.
Line cord is improperly seated in
socket.
Circuit breaker is tripped.
Corrective Action
Turn the switch to the ON position.
Plug treadmill into a dedicated 20
amp circuit.
Using a voltmeter, verify power at
outlet. If no power exists, reset
circuit breaker at panel.
Replace line cord. Contact Life
Fitness Customer Support Services.
Inspect power connection at wall
outlet and at machine for proper
contact.
Verify that circuit breaker is not
open. If open, reset circuit breaker.
The location of the circuit breaker is
on the outside of the treadmill, next
to the ON/OFF switch. The breaker
is a circular disk with a white button.
The white button will have popped
out. Press the white button at it's
center to reset the circuit breaker.