Installing On Fabricated Mounting; Installing Optional Casters - Wells CONVECTIONM4200-3S Owner's Manual

With optional prep top
Table of Contents

Advertisement

INSTALLATION (continued)
WARNING:
Electric
Shock hazard
All servicing requiring
access to non-insulated
electrical components
must be performed by a
factory authorized
technician.
DO NOT open any access
panel which requires the
use of tools. Failure to
follow this warning can
result in severe electrical
shock.
DIMENSIONS
Fabricated Mounting
EQUIPMENT SET-UP
1. CURB or COUNTER MOUNTING
a. Setup the appliance only on a firm, level, non-combustible
surface. Verify local codes for requirements. Concrete, tile,
terrazzo or metal surfaces are recommended. Metal over
combustible material may not meet code for non-combustible
surfaces.
b. Appliance is approved for installation with zero clearance at
bottom.
c. Recommend at least 3" clearance on sides and back to allow
adequate air flow.

2. INSTALLING OPTIONAL CASTERS

a. Install casters, one on each corner of the appliance, in the
holes provided. Locking casters must be installed on the
FRONT of the appliance.
b. Set up the appliance only on a firm, level, non-combustible
surface. Verify local codes for requirements. Concrete, tile,
terrazzo or metal surfaces are recommended. Metal over
combustible material may not meet code for non-combustible
surfaces.
c. LEVELING: Verify that the appliance sits firmly on all four
casters when in its normal operational position. With a spirit
level, check that the appliance is level front-to-back and
side-to-side.
3. INSTALLING OPTIONAL LEGS (NOTE: Legs are not provided
and must be purchased separately.)
a. Install adjustable legs, one on each corner of the appliance, in
he holes provided.
b. Set up the appliance only on a firm, level, non-combustible
surface. Verify local codes for requirements. Concrete, tile,
terrazzo or metal surfaces are recommended. Metal over
combustible material may not meet code for non-combustible
surfaces.
c. LEVELING: Verify that the appliance sits firmly ON ALL FOUR
LEGS. With a spirit level, check that the appliance is level
front-to-back and side-to-side.

4. INSTALLING ON FABRICATED MOUNTING

a. Mounting must be capable of safely supporting 350 pounds
(165 Kg.), and must be fabricated to the dimensions shown at
left:
b. Attach the appliance securely to the mounting with
four 3/4"-10 x 1" bolts.