Oil level
The machine must be switched off and placed on a flat
surface when you check the oil level.
Unscrew the oil cap, clean the dipstick located on the cap
and insert the cap again without screwing it down. Check
the oil level on the dipstick.
When the oil level is low, top up using engine oil to the edge
of the oil refill hole.
Only use recommended engine oil.
14 – English
FUEL HANDLING
Fueling
!
Clean around the fuel cap. Clean the fuel and oil tank
regularly. The fuel filter should be changed at least once a
year. Contamination in the tanks causes malfunction.
Always move the machine about 3 metres from the refuelling
position before starting.
WARNING! Taking the following
precautions, will lessen the risk of fire:
Do not smoke or place hot objects near
fuel.
Always shut off the engine before
refuelling.
Always stop the engine and let it cool for a
few minutes before refuelling.
When refuelling, open the fuel cap slowly
so that any excess pressure is released
gently.
Tighten the fuel cap carefully after
refuelling.
Always move the machine away from the
refuelling area before starting.