TESTING CONDITIONS (Complete Systems)
Temperature: 77°F ± 2°F
Pressure: 50 psi
This system has been tested and shown to operate at its calculated recovery rating under standard test
conditions.
DIMENSIONS
Filter Assembly
Storage Tank - Standard
Refer to your Installation and Operating Instructions and printed limited Warranties for more specific
product information. To avoid contamination from improper handling and installation, your system should
only be installed and serviced by your Culligan Man. Performance will vary based on local water conditions. The
substances reduced by this system are not necessarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that
you ask your local independent Culligan dealer. Performance will vary depending on local water conditions. The
substances reduced by this system are not necessarily in your water.
APPLICATION GUIDELINES
The Good Water Machine
is designed for use on potable water supplies meeting the guidelines outlined
in Table 1. The system should be installed on your home's cold water line. The flushing stream should
discharge through an approved siphon break as illustrated in Figure 1. Installation of this system must
comply with state and local laws and regulations.
TABLE 1
Pressure
Temperature
Total Dissolved Solids (TDS)
pH
Chlorine
2
Chloramine
Turbidity
Hardness
Iron
Bacterial Quality
1 See the Technical Manual for all applications where TDS exceeds 1000 ppm (1000 mg/L). A booster pump is
strongly recommended.
2 The reverse osmosis membrane filter used in this system may be damaged by chlorine. This system includes
activated carbon which protects this element by reducing chlorine. Influent chlorine should not exceed 3 mg/L.
3 A softener is strongly recommended for water over 10 gpg.
pH: 7.5 ± 0.5
Turbidity: < 1 NTU
7.5" W x 3" D x 16.5" H (20 cm W x 8 cm D x 42 cm H)
11" Diameter x 15" H (28 cm Diameter x 38 cm H)
Influent Water Characteristic
40 - 120 psi (280 - 827 kPa)
33 - 100°F (1 - 38°C)
1
0 - 4000 ppm ( 0 - 4000 mg/L)
5 - 10
0 - 3 ppm ( 0 - 3 mg/L)
0 - 3 ppm ( 0 - 3 mg/L)
0 - 10 NTU
0 - 20 gpg
0 - 1 ppm (0 - 1 mg/L)
Potable