Culligan Gold Series Owner's Manual page 15

Gold series automatic water conditioner
Hide thumbs Also See for Gold Series:
Table of Contents

Advertisement

Note: This Setting appears during Aqua-Sensor Programming.
Pressing the "STATUS" key will save the setting and move to the next programming step.
13. Backwash Time - This setting is used to program the back-
wash. The time of the cycle is kept in minutes. The dis-
play will show the "BACKWASH" and "MINS" icons and
the cycle time in the right most digits. Adjust the value
with the "+" or "-" keys.
Note: This Setting appears during Aqua-Sensor Programming.
Pressing the "Status" key will save the setting and move to the next programming step.
14. Brine Drain/Slow Rinse - This setting is used to set the
time in minutes for brine drain/slow rinse cycle. The dis-
play will show the "BRINE RINSE" and "MINS" icons and
the cycle time in the right most digits. Adjust the value
with the "+" or "-" keys.
Note: This Setting appears during Aqua-Sensor Programming.
Pressing the "Status" key will save the setting and move to the next programming step.
15. Batch Set Point - This setting is used to set the trip point for regeneration when in flow meter oper-
ation. It will only appear if a flow meter is connected, and 'dEFLtS' set to 'NO'. The programmed
setting displays the actual set point to trigger regeneration. The display will show the "REGEN" icon
and "BAtch" for two seconds and then display the "REGEN" and "GALLONS" icons and the setting
numbers to adjust. Adjust the value with the "+" or "-" keys.
REGEN
BAEEH
Pressing the "Status" key will save the setting and move to the next programming step.
10
BACKWASH
60
BRINE RINSE
REGEN
0008 70
GALLONS
MINS
MINS
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gold 9"Gold 10"Gold 12"Gold 14"

Table of Contents