INSTALLATION INSTRUCTIONS
Sample Wiring Diagrams
Gas or Electric Heat
Dual Transformer 5 Wire, 1 Stage Cooling, 1 Stage Heating
Residential Gas or Electric Heat, Electric Cool, split systems & package units.
For jumper configuration see pages 14 and 15.
Remove the
factory installed
jumper between
RC and RH
Heating System
POWER
HEAT
FAN
GAS OR
ELECTRIC HEAT
Cooling System
POWER
COOL
COMPRESSOR
*
If a common wire is used it must be connected to the furnace common terminal.
If a common wire is not used the thermostat must be powered by two AA alkaline
batteries. These batteries must be replaced (page 6) each year or when the Low
Battery indicator is displayed (page 3).
*
Common wire optional
C O/B Y W G RC RH