Download Print this page

Kidde i9060CA User Manual page 14

9 v battery operated

Advertisement

Maintenance
Alarm Removal
If the smoke alarm tamper resist feature has been activated, refer
to the Alarm Tamper Resist Feature section for removal
instructions.
To remove the alarm from the mounting plate, rotate the alarm in
the direction of the "OFF" arrow on the cover.
Battery Replacement
This alarm has a low battery monitor circuit which will cause the
alarm to "chirp" approximately every 30-40 seconds for a
minimum of seven (7) days when the battery gets low. Replace the
battery when this condition occurs.
Models i9060CA and i9080CA use a 9 V carbon zinc battery
(alkaline and lithium batteries may also be used). A fresh battery
should last for one year under normal operating conditions.
Use only the following 9 volt batteries for replacement:
Carbon-Zinc Type
Alkaline Type
Lithium Type
These batteries can be purchased at your local retailer.
WARNING: Use only the batteries specified above. Use of different
batteries than the recommended ones, may have a detrimental
effect on the smoke alarm. A good safety measure is to replace the
battery at least once a year, or at the same time you change your
clocks for daylight saving time. Be sure to follow the battery
installation instructions printed on the back of the alarm.
13
Eveready 1222
Gold Peak 1604P or 1604S
Energizer 522
Duracell MN1604 or MX1604
Gold Peak 1604A
Panasonic 6AM6, 6AM-6, 6AM-6PI,
6AM6X and 6LR61 (GA)
Ultralife U9VL-J