What To Do If The Alarm Sounds
Never restart the source of a CO problem until it
has been fixed. NEVER IGNORE THE ALARM!
The CO sensor meets the alarm response time requirements of
BS7860. Standard alarm times are as follows:
At 45 PPM, the unit must not alarm before 60 minutes.
At 150 PPM, the unit must alarm within 10-30 minutes.
At 350 PPM, the unit must alarm within 6 minutes.
This carbon monoxide alarm is designed to detect
carbon monoxide gas from ANY source of
combustion. It is NOT designed to detect any other
gas.
British gas and some gas engineers will perform CO
inspections, some may charge for this service. It's advisable to
inquire about any applicable fees prior to having the service
performed. Kidde Safety will not pay for, or reimburse, the
owner or user of this product, for any repair or dispatch calls
related to the alarm sounding.

Battery Replacement

If any form of battery failure is detected the red LED light will
flash and the unit will "chirp" one time, followed by the
warning message "LOW BATTERY." This cycle will occur
once every minute for the first hour. After the first hour, the
red LED light will continue flashing accompanied by the
chirp only sound every 60 seconds.