Fault Codes (N64X, N64Xxx, N64Xim, N64Ximxx, N84Xim N84Xxx, N84Xim, And N84Ximxx Models) - Norcold N62X Owner's Manual

6 cu.ft. or 8 cu. ft., 2 or 3 way refrigerators
Hide thumbs Also See for N62X:
Table of Contents

Advertisement

Available languages

Available languages

Fault Codes (N64X, N64XXX, N64XIM, N64XIMXX, N84X, N84XXX, N84XIM, and
N814XIMXXmodels)
Fault Codes
No display.
"dr"
Audible alarm also.
"no" "FL"
Audible alarm also.
"no" "AC"
Audible alarm also.
"dc" "LO"
Temperature number
flashes when TEMP
SET button is pushed.
"AC" "rE"
Audible alarm also.
"dc" "rE"
Audible alarm also.
"AC" "HE"
Audible alarm also.
"dc" "HE"
Audible alarm also.
"Sr"
Audible alarm also.
Owner's Manual 16
Fault Code Meaning
DC voltage is
unavailable to
the refrigerator
control panel or the
refrigerator is OFF.
The door was open for
more than 2 minutes.
The burner did not
ignite or re-ignite.
AC voltage is
unavailable to the
refrigerator control
panel.
DC voltage to the
refrigerator control
panel is too low.
The refrigerator is
operating on the
"Back Up Operating
System".
This is a fault within
the refrigerator
controls.
This is a fault within
the refrigerator
controls.
This is a fault within
the refrigerator
controls.
This is a fault within
the refrigerator
controls.
This is a fault within
the refrigerator
controls.
Check:
- That the refrigerator is ON.
- That the battery charging equipment of the vehicle is operational.
- That the AC/DC converter is operational (if applicable).
- See your dealer or authorized Norcold Service Center.
Close the door.
Check:
- That the valve of the propane gas tank(s) is open.
- That the propane gas is at the correct pressure.
- That the manual shut off valve of the refrigerator is open.
- That there is no air in the propane gas supply line. See "Removing air
from the propane gas supply lines" section of this manual.
- See your dealer or authorized Norcold Service Center.
Check:
- That the refrigerator is plugged into a serviceable outlet.
- That the fuse or circuit breaker or the vehicle is intact.
- That the vehicle generator is operational (if applicable).
- See your dealer or authorized Norcold Service Center.
Check:
- That the battery charging equipment of the vehicle is operational.
- That the AC/DC converter is operational (if applicable).
- See your dealer or authorized Norcold Service Center.
This is not owner serviceable. See your dealer or authorized Norcold
Service Center.
This is not owner serviceable. See your dealer or authorized Norcold
Service Center.
This is not owner serviceable. See your dealer or authorized Norcold
Service Center.
This is not owner serviceable. See your dealer or authorized Norcold
Service Center.
This is not owner serviceable. See your dealer or authorized Norcold
Service Center.
This is not owner serviceable. See your dealer or authorized Norcold
Service Center.
Corrective Actions