Filter Options; Model Selection Procedure - Greenheck SQ Brochure & Specs

Centrifugal inline fans direct and belt drive
Table of Contents

Advertisement

Filter Options

D
C
Model
A
22
1
8
SQ-60 - 75
(562)
45
5
8
SQ-80 - 95
D
(1159)
47
1
4
SQ-100
(1200)
52
3
16
SQ-120
(1326)
C
46
3
8
SQ-130
(1178)
52
3
8
SQ-140
(1330)
Optional cover varies
51
3
8
SQ-160
with motor size.
(1305)
Recommend 24 in.
50
clearance.
5
8
BSQ-70 - 80 - 90
(1286)
47
1
4
BSQ-100
(1200)
52
3
16
BSQ-120
(1326)
46
3
8
BSQ-130 - 130HP
(1178)
52
3
8
BSQ-140 - 140HP
(1330)
51
3
8
BSQ-160 - 160HP
(1305)
55
1
16
BSQ-180 - 180HP
(1399)
66
11
16
BSQ-200 - 200HP
(1694)
68
7
8
BSQ-240 - 240HP
(1749)
72
1
8
BSQ-300 - 300HP
(1832)
(1168)
79
1
4
BSQ-360 - 360HP
(2013)
(1321)
93
1
8
BSQ-420
(2365)
(1473)
Note: 24-inch side clearance is recommended for accessing and removing filters.
All dimensions in inches (millimeters) and weight (WT.) in pounds (kilograms).
8
The filter box is designed to provide a compact and convenient clean air solution.
Factory assembled as a single unit, this fan eliminates the costly process of
designing, fabricating, and installing special remote filter box assemblies. Both
the fan and filter section feature removable access panels on both sides to
remove and replace filters, making fan maintenance simple and fast.
Model SQ
A
D
C
B
C
D
WT. Filter Size
12
8
1
40
10 x 12
7
8
(305)
(225)
(25)
(18)
(254 x 305)
15
11
1
74
14 x 25
7
8
A
D
(381)
(302)
(25)
(34)
(356 x 635)
17
13
1
88
16 x 20
7
8
(432)
(352)
(25)
(40)
(406 x 508)
19
15
1
114
16 x 25
7
8
(483)
(403)
(25)
(52)
(406 x 635)
C
21
17
1
120
20 x 20
7
8
(533)
(454)
(25)
(54)
(508 x 508)
23
19
1
174
20 x 25
7
8
(584)
(505)
(25)
(79)
(508 x 635)
26
22
1
246
20 x 20
7
8
(660)
(581)
(25)
(112)
(508 x 508)
15
11
1
117
14 x 25
7
8
(381)
(302)
(25)
(53)
(356 x 635)
17
13
1
120
16 x 20
7
8
(432)
(352)
(25)
(54)
(406 x 508)
19
15
1
144
16 x 25
7
8
(483)
(403)
(25)
(79)
(406 x 635)
21
17
1
140
20 x 20
7
8
(533)
(454)
(25)
(64)
(508 x 508)
23
19
1
181
20 x 25
7
8
(584)
(505)
(25)
(82)
(508 x 635)
26
22
1
294
20 x 20
7
8
(660)
(581)
(25)
(133)
(508 x 508)
28
23
1
344
20 x 25
7
1
8
2
(711)
(606)
(38)
(156)
(508 x 635)
12 x 25
32
27
1
441
(305 x 635)
7
1
8
2
16 x 25
(813)
(708)
(38)
(200)
(406 x 635)
20 x 25
39
34
1
573
(508 x 635)
7
1
8
2
16 x 25
(991)
(886)
(38)
(260)
(406 x 635)
46
41
1
759
20 x 25
7
1
8
2
(1064)
(38)
(344)
(508 x 635)
16 x 25
52
47
1
957
(406 x 635)
7
1
8
2
20 x 25
(1216)
(38)
(434)
(508 x 635)
16 x 25
58
53
1
1185
(406 x 635)
7
1
8
2
20 x 25
(1368)
(38)
(538)
(508 x 635)
D
C
D
B
C
Optional cover varies
with motor size.
Recommend 24 in.
Filter
clearance.
Quantity
1
1

Model Selection Procedure

2
1. Calculate system pressure drop and CFM
2
B
requirements (not including filters).
2
2. Make a preliminary model size selection.
2
3. Calculate a filter pressure drop for the
preliminary model size selected in step 2 using
4
the equation:
1
cfm
P = Fx (
10,000
2
4. Add the filter pressure drop (P) to the system
2
pressure drop and make a revised model
size selection. Use the charts on the left to
2
determine filter factor (F).
2
4
4
Model Size
3
3
SQ
4
60-65-70-75
80-85-90-95 70-80-90
4
100
120
8
130
10
140
160
5
5
10
A
Model BSQ
A
2
)
1 in.
1 in.
2 in.
Aluminum
Paper
Aluminum
Filter
BSQ
Filters
Filters
Factor (F)
186
318.06
251.1
21.8
37.278
29.43
100
8.72
14.9112
11.772
120
5.58
9.5418
7.533
130
5.58
9.5418
7.533
140
3.57
6.1047
4.8195
160
2.09
3.5739
2.8215
180
1.34
2.2914
1.809
200
0.77
1.3167
1.0395
240
0.41
0.7011
0.5535
300
0.33
0.5643
0.4455
360
0.15
0.2565
0.2025
420
0.13
0.2223
0.1755
D
B
C
D
C
B
2 in.
Paper
Filters
303.18
35.534
14.2136
9.0954
9.0954
5.8191
3.4067
2.1842
1.2551
0.6683
0.5379
0.2445
0.2119

Advertisement

Table of Contents
loading

Table of Contents