STARTUP

Always use this startup procedure to ensure that the unit
is started safely and properly.
1. Check oil levels.
Engine: Add SAE 30 or 10W–30 weight detergent oil
as necessary.
Pump: Add SAE 20 or 30 weight non–detergent oil or
genuine Cat pump oil as necessary.
Gear Reducer (2040 and 2540): Add SAE 90 gear oil
as necessary . The 1535 uses the oil in pump
crankcase.
NOTE:
All units are equipped with a low–oil sensor that
shuts the engine off if the oil level falls below a
certain level. If the unit stops unexpectedly
check both the oil and the fuel levels. Check the
oil level each time the unit is refueled.
2. Check fuel level.
WARNING
DO NOT refuel a hot engine. Refueling a hot
engine could cause a fire. Use only fresh, clean
regular or unleaded gasoline. Close the fuel
shutoff valve during refueling.
3. Turn on the water supply.
CAUTION
Never run the unit dry. Costly damage to the pump
will result. Always be sure the water supply is
completely turned on before operating.
4. Trigger the gun until water sprays from the tip
indicating that the air is purged from the system.
5. Open the fuel shutoff valve. Be sure the spark plug
ignition cable is pushed firmly onto the spark plug. On
those units equipped with an ignition shutoff switch,
put the switch in the "on" position and put the throttle
in the "run" position.
6. Start the engine.
NOTE:
For easier starting, have one person start the
pressure washer while another person triggers
the spray gun.
308–530
If the engine is cold, completely close the engine
choke. Grasp the starter rope, brace one foot on the
pressure washer chassis and pull rope rapidly and
firmly. Continue holding the rope as it returns. Pull
and return the rope until the engine starts. In cool
weather, the choke may have to be kept closed for 10
to 30 seconds before opening it to keep the engine
running. Otherwise, open the choke as soon as the
engine starts.
If the engine is warm, leave the choke open, or just
partly close it. Start the engine as described in the
preceding paragraph. When it starts, be sure to open
the choke completely.
On recoil start engines, never let the starter rope
return by itself. It could jam the recoil system.
,
7. ALWAYS engage the gun'
whenever you stop spraying, even for a moment, to
reduce the risk of fluid injection or splashing in the
eyes or on the skin if the gun is bumped or triggered
accidentally.
8. ALWAYS observe the following CAUTIONS to avoid
costly damage to the pressure washer.
DO NOT allow the pressure washer to idle for more
than 10 minutes. Doing so may cause the
recirculating water to overheat and seriously
damage the pump. Turn off the pressure washer if it
will not be spraying or cleaning at least every 10
minutes. If heated inlet water is used, reduce this
time further.
DO NOT run the pump dry , which will quickly
damage the pump. Be sure the water supply is fully
turned on before starting the pump.
DO NOT operate the pressure washer with the inlet
water screen removed. This screen helps keep
abrasive sediment out of the pump, which could
clog or scratch the pump. Keep this screen clean.
DO NOT pump caustic materials; such materials
may corrode the pump components.
9. See the chemical injector or sandblaster kit manual
for detailed cleaning information if these accessories
are used.
CAUTION
s trigger safety latch
CAUTION

Advertisement

Table of Contents
loading

Table of Contents