15 SEC
safety OFF
FLUSH
Note: Inspect fittings for leaks.
leaks occur, turn sprayer OFF immediately. Do Pressure Relief in Cleanup, 1. – 3.
on page 17. Tighten leaky fittings. Repeat Startup, 1. – 5. If no leaks, continue to
trigger gun until system is thoroughly flushed. Proceed to 6.
309408
Startup
5. Set pump switch ON.
– Pump/clutch is now active –
6. Increase pressure enough to start pump
stroking and allow fluid to circulate for 15
seconds; turn pressure down, turn prime
valve horizontal.
7. Take spray gun trigger safety OFF.
ti2870a
8. Hold gun against grounded metal flushing pail.
Trigger gun and increase fluid pressure slowly
until pump runs smoothly.
Do not stop leaks with your hand or a rag! If